title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
1012/1330

This page is the summary of page 1012 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

AC-DC Power Supplies Enclosed TypeInstruction ManualTable 6.3 Matching connectors and terminals on CN101 and CN501Connector Housing Terminal MfrCN101 1-178139-5 1-178129-6 1-175218-5 equivalent goodsTE ConnectivityCN501 178306-5 178289-6 1-353717-5 equivalent goods*Keep drawing current per pin below 8.5A? -R3- Option -R3 models provide AUX1 (12V), AUX2 (5V),remote ON/OFF control and alarms (PR,PG alarm).-Please refer to the optional parts for the dedicated harness.-Please contact us for details about appearance.+Vout-VoutAUX1AUX1GFig.6.4 When using AUX1×Do not connectCN3! AUX2 5V0.5A (convection cooling), 5V1A (forced air)- Output AUX2 is provided from CN3. AUX2 (5V±5%) can beused to power up remote control or other circuits.- AUX2 has been isolated from other circuit (input, output, FG,RC).- AUX2 output is also stopped due to thermal protection andovervoltage protection.Please contact us for details.- Do not exceed the current rating, it may causes malfunction orfailure of the internal circuitry.Fig.6.3 Example of option -R3Table 6.4 Pin assignments of CN3Pin no.Function1AUX1: AUX1 (12V1A)2AUX1G : AUX1 (GND)3AUX2: AUX2 (5V1A)4AUX2G : AUX2 (GND)5AUX2: AUX2 (5V1A)6AUX2G : AUX2 (GND)7RC: Remote ON/OFF8RCG: Remote ON/OFF (GND)9PG: PG Alarm10PGG: PG Alarm (GND)11PR: PR Alarm12PRG: PR Alarm (GND)Table 6.5 Matching connectors and terminals on CN3Connector Housing Terminal MfrS12B- PHDR-Reel : SPHD-002T-P0.5CN3Loose : BPHD-001T-P0.5 *1 J.S.T.PHDSS 12VSBPHD-002T-P0.5 *1*1 The manufacturer can offer only ratchet hand toolCN3! AUX1 12V0.3A (convection cooling), 12V1A (forced air)11 121 2- This power supply is equipped with an auxiliary 12V outputAUX1 (12V?5%) for forced air cooling which is available fromCN3.- AUX1 is not isolated from the main output circuit.- Do not connect AUX1G- to -Vout as current may fl ow throughAUX1 (fi g 6.4).- Do not exceed the current rating, it may causes malfunction orfailure of the internal circuitry.!Remote ON/OFF- You can operate the remote ON/OFF function by sendingsignals to CN3. Please see Table 6.6 for specifications andFig.6.5 for connecting examples.- Remote ON/OFF circuits (RC and RCG) are isolated from input,output FG and AUX.- Please note the following when using the remote ON/OFF function.1 Turns on by drawing current to RC.2 The current fl own to RC is a 5mA typ (maximum 25mA).3 If the output voltage is turned off through the remote ON/OFFcircuit, AUX1 stops.4 If current of a value not listed in Table 6.6 is applied between RCand RCG, the output voltage may not be generated normally.5 Please wire carefully. If you wire wrongly, the internal componentsof a unit may be damaged.* If the output of an external power supply is within the range of4.5 - 12.5V, you do not need a current limiting resistor R1. Ifthe output exceeds 12.5V, however, please connect the currentlimiting resistor R1.R1 Recommended resister [W] Ri : 780[W]V1 - (1.1 + Ri×0.005)R1=0.005Table 6.6 Specifi cations of remote ON/OFFFig.6.5 RC circuit example ?R3Output on SW short (3mA min)SW LogicOutput off SW open (0.1mA max)AEA-16