Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
AC-DC Power Supplies Enclosed TypeInstruction ManualWire(a)Flat-blade screwdriverWireWire insertionholeRelease hole(b)Wire insertionholeRelease holeFig.6.8 Connecting method of Ferrule terminal and Solid wire-How to connect the stranded wireStep1: Insert a fl at-blade screwdriver into the release hole. (Referto the fig.6.9(a).)Step2: Insert the wire until the electrode is not visible with the fl atbladescrewdriver inserted in the release hole. (Refer to thefi g.6.9(b).)Step3: Remove the fl at-blade screwdriver from the release hole.(Refer to the fig.6.9(c).)Step4: Pull the wire lightly in order to make sure it is fi xed.? -P5- Overcurrent protection will be changed to shut down mode fromhic-cup mode.- Please contact us for any other conditions.? -I4- Option -I4 models provide MODBUS-RTU communicationinterface, AUX1(12V), AUX2(5V), remote ON/OFF control andalarms(PG, PR alarm).- Please refer to "AEA Series MODBUS Communication Manual"for details.- For AUX1, AUX2 and alarms, Please refer to option "-R3".- AUX2 output is not stopped due to thermal protection and overvoltageprotection.- A, B and SGND terminal are not isolated from AUX2.- A, B and SGND terminal are isolated from input, output, FG,AUX1, RC, PG and PR terminals.- The connector CN4 is the interface for MODBUS communication.- When setting the output voltage using MODBUS communication,do not use the built-in potentiometer.If you want to set theoutput voltage with MODBUS communication after adjusting theoutput voltage by the potentiometer, please return to the initialstate refer to MODBUS Communication Manual .CN4CN3(a)(b)(c)Fig.6.9 Connecting method of Stranded wire-How to release the Ferrule terminal, Solid wire and StrandedwireStep1: Insert a fl at-blade screwdriver into the release hole. (Referto the fig.6.10(a).)Step2: Remove the wire with the fl at-blade screwdriver inserted inthe release hole. (Refer to the fi g.6.10(b).)Step3: Remove the fl at-blade screwdriver from the release hole.(Refer to the fig.6.10(c).)(a)(b)(c)Fig.6.10 Releasing method of Ferrule terminal, Solid wire and Stranded wireFig.6.11 Example of option -I4Table 6.11 Pin assignments of CN4Pin no.Function1 N.C.2 N.C.SGND : Signal ground3(Same potential as AUX2G)SGND : Signal ground4(Same potential as AUX2G)B : RS485 differential signal5(?, Inverted)B : RS485 differential signal6(?, Inverted)A : RS485 differential signal7(+, Non-Inverting)A : RS485 differential signal8(+, Non-Inverting)Do not connect anything to N.C. pinsCN47182AEA-18