title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
108/916

This page is the summary of page 108 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

HCA-seriesDeratingHCA? Derating curve depends on Input voltageLoad factor[%]10090180 200 528Input voltage[VAC]? Derating curve depends on Output voltage! The unit should be used by the conduction cooling such as the water-cooled plate.! The temperature of both points A and B has to be within the derating curve.! Ambient temperature must keep between -10C and 70C.10080Output voltage>110%Output voltage≦110%Load factor[%]60402000 10 20 30 40505560Baseplate temperature [C]Baseplate temperature measuring point ABaseplate temperature measuring point BInstruction Manual◆It is neccessary to read the“Instruction Manual”and“Before using our product”before you use our product.Instruction Manualhttps://www.cosel.co.jp/redirect/catalog/en/HCA/Before using our producthttps://en.cosel.co.jp/technical/caution/index.htmlHCANOTICEBasic Characteristics DataModelCircuit methodSwitchingfrequency[kHz]Inputcurrent[A] *InrushcurrentprotectionPCB/PatternMaterialSinglesided DoublesidedSeries/Paralleloperation availabilitySeriesoperationParalleloperationHCA3500TFActive filter130Phase-shift Full-bridge(Primary) 95converter(Secondary) 19011.5Thermistor+IGBTFR-4 Yes Yes Yes* The value of input current is at 200VAC input and rated load.HCA-6? 106 ?