AC-DC Power Supplies Medical TypeGHA300F, GHA500FInstruction Manual1.8 Isolation!For a receiving inspection, such as Hi-Pot test, gradually increase(decrease) the voltage for the start (shut down). Avoid using Hi-Pot tester with the timer because it may generate voltage a fewtimes higher than the applied voltage, at ON/OFF of a timer.!When you test a unit for isolation between the input and output,input and the terminal FG or between the output and the terminalFG, short-circuit between the output and the terminals RCG, PGGand AUXG.2 Series Operation andParallel OperationPlease evaluate carefuly and test for any possible failure modes.!Hot-swap or Hot-plug is not available.3 TemperatureMeasurement Point? GHA500F!Cooling methodConduction cooling, forced air and convection cooling are available.The combination of the cooling method makes mechanical designfl exible.2.1 Series Operation!Series operation is available by connecting the outputs of two ormore power supplies with the same output voltage, as shown below.Output current in series connection should be lower than thelowest rated current in each unit.Remarks :Please be sure to have enough cooling in case one of the powersupply stops due to activation of the protection circuitry.FAN6)conduction cooling + forced air(Variable speed FAN)Combination: chassis: Heat dissipationPower +Supply -Power +Supply -LoadPower +Supply -Power +Supply -LoadLoad1)convectionSeal case2)conduction cooling3)forced airFANFig.2.1 Examples of connecting in series operation2.2 Parallel OperationCombinationCombination!Parallel operationParallel operation is possible with option”-P”.Parallel operation is not available for the standard unit, please referto the listed options.!Redundancy operationRedundancy operation is available by wiring as shown below.PowerSupplyPowerSupply+-+-I1I2I3LoadFig.2.2 Example of redundancy operation!Even a slight difference in output voltage can affect the balancebetween the values of I1 and I2.Please make sure that the value of I3 does not exceed the ratedcurrent of a power supply.I3 [ the rated current value4)convection + conduction cooling 5)conduction cooling + forced airFig.3.1 Cooling method CombinationIn order to determine if the power supply operates according toour specifi cations, the maximum operating temperature and temperaturemeasuring points are shown in table 3.1., for reference.? GHA300F!Cooling methodBoth Forced air and convection cooling are available.(Fig 3.1 1),3),6)cooling method).Remarks:!For proper operation of the power supply, please note the following:-The temperature rise and heat dissipation of the converter must beconsidered.-Conditions varies with environment and input voltage.GHA-18