title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
110/916

This page is the summary of page 110 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

AC-DC Power Supplies Enclosed TypeHFA3500TFOrdering informationHF A 3500 TF -OO -O1 2 3 4 5 6HFAR1 Series name2 Single output3 Output wattage4 3 phase full range input5 Output voltage6 OptionalR : with Remote ON/OFFPositive logic controlG : Low leakage currentI4 : with MODBUS interfaceMODELHFA3500TF-48HFA3500TF-65MAX OUTPUT WATTAGE[W]35043510DC OUTPUT48V 73A65V 54ASPECIFICATIONSMODELHFA3500TF-48HFA3500TF-65VOLTAGE[VAC]*1180 - 528 3f3-wire (Available to 3f 4-wire as well (without N phase) )CURRENT[A]FREQUENCY[Hz]50 / 60 (45 - 66)ACIN 200V (Io=100%) 91typ 92typEFFICIENCY[%]INPUTACIN 400V (Io=100%) 93typ 94typPOWER FACTORINRUSH CURRENT[A]LEAKAGE CURRENT[mA]3 max (ACIN 480V 60Hz, Io=100%, Complies with IEC62368-1)VOLTAGE[V]4865CURRENT[A]7354LINE REGULATION[mV]192max260maxLOAD REGULATION[mV]300max450maxRIPPLE[mVp-p]OUTPUTTEMPERATURE0 to +50C390max530maxREGULATION[mV]-10 to +0C480max650maxSTART-UP TIME[ms]400 typ (ACIN 200/400V, Io=100%)HOLD-UP TIME[ms]20 typ (ACIN 200V, Io=55%) / 10 typ (ACIN 200V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]24.00 to 55.2032.50 to 74.75OUTPUT VOLTAGE SETTING[V]48.00 to 48.4865.00 to 65.65OVERCURRENT PROTECTIONWorks over 105% of rating (Recovers automatically, Hiccup overcurrent)OVERVOLTAGE PROTECTION[V]57.60 to 67.2078.00 to 91.00PROTECTIONREMOTE SENSINGProvidedCIRCUIT ANDOTHERSREMOTE ON/OFFProvidedDC_OK LAMPLED (Blue)ALARM LAMPLED (Amber)Input - Output,CN1, CN2, CN34,243VAC 1minute, Cutoff current = 20mA, 500VDC 50MW min (At room temperature)Input - FG2,829VAC 1minute, Cutoff current = 20mA, 500VDC 50MW min (At room temperature)ISOLATIONOutput, CN1, CN2 - FG2,000VAC 1minute, Cutoff current = 10mA, 500VDC 50MW min (At room temperature)Output, CN1, CN2 - CN3500VAC 1minute, Cutoff current = 10mA, 500VDC 50MW min (At room temperature)CN3 - FG500VAC 1minute, Cutoff current = 10mA, 500VDC 50MW min (At room temperature)OPERATING TEMP.,HUMID.AND ALTITUDE-10 to +70C (Refer to“Derating”), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) maxENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each along X, Y and Z axisSAFETY ANDAGENCY APPROVALSUL62368-1, EN62368-1, C-UL (equivalent to CAN/CSA-C22.2 No.62368-1)NOISE REGULATIONSCONDUCTED NOISEComplies with FCC Part 15-A, FCC Part18-A, CISPR11-A, CISPR32-A, EN55011-A, EN55032-A, VCCI-AOTHERS*1Output derating is required at 180 - 200VAC. Refer to“Derating”.*2The value is primary surge. The current of input surge to a built-in EMI/EMS Filter (0.2ms or less) is excluded. More than 3 sec. to re-start.*3Measured by 20MHz oscilloscope or Ripple-Noise meter (equivalent to KEISOKUGIKEN : RM104). Please refer to the instruction manual 1.7.*Sound noise may be generated by power supply in case of pulse load.HFA-2? 108 ?