title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
1129/1330

This page is the summary of page 1129 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

AC-DC Power Supplies Medical TypeInstruction ManualCN3+V +V*1 If the external voltage applied to the RC terminals is 4.5-12.5V, the current limiting resistor is not necessary. If the voltageapplied is more than 12.5V, make sure the current limitingresistor R is used.V.ADJFig.5.1 Front view of option-V (PJMA600F)-V+VCN3Fig.5.2 Front view of option-V (PJMA1000F)-V12The value of the current limiting resistor is obtained by the followingformula:R[W]= Vcc-(1.1+RiX0.005) Vcc : External Power Source0.005*Note that reversed connection damages internal components ofthe power supply.*The remote control circuit is isolated from input, output and FG.■Remote on/off control for PJMA300F-Remote control connectors are added. Contact us for more details.-Make sure there is an interval of more than 2 seconds in the on/off cycle. If the interval is shorter, the start-up time may becomelonger (approx. 2 seconds).CN1+VV.ADJCN11 RC2 RCG12+V●?RFig.5.3 Front view of option-V (PJMA1500F)-The ?R option makes it possible to switch on or off the output byapplying voltage to the RC terminals of the power supply froman external power source.-The appearance of the option ?R models is different from that ofthe standard models.-Designated harnesses for the RC terminals are available forsale. See Optional Parts for more details.-The ?R option models have extra connectors. Please contact usfor more details.Table 5.2 Remote on/off operating conditionsModel NameBuilt-inResistorRi [ W ]Voltage between RCand RCG [V]Output ON Output OFFInputCurrent[mA]PJMA300F,PJMA600F,PJMA1000F,PJMA1500F7804.5 - 12.50 - 0.5(20max)R *1CN3SWRCInside of a PowerSupplyRi+V -V -VAC AC(N) (L)FGFig.5.5 Example of option -R (PJMA300F)Table 5.3 Pin configuration and function of CN1 (PJMA300F)PINFUNCTION1 RC : Remote ON/OFF2 RCG :Remote ON/OFF (GND)Table 5.4 Mating connectors and terminals on CN1 (PJMA300F)Connector Housing Terminal MfrCN1 XARR-02V XAP-02V-1 SXA-001T-P0.6 J.S.T.■Remote on/off control for PJMA600F, PJMA1000F and PJMA1500F-The appearance of the ?R option model is different from that ofthe standard model as CN1 is added. Contact us for more details.External PowerSourceInput CurrentRCGCN1+V +V -V -VFGAC(N)AC(L)Remote ON/OFF connector (Optional)Fig.5.4 Example of using a remote ON/OFF circuitV.ADJFig.5.6 Front view of option -R (PJMA600F)March 15, 2023PJMA-16