title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
1130/1330

This page is the summary of page 1130 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

AC-DC Power Supplies Medical TypeInstruction ManualCN1CN1H-SN-31(install)-V-VFG AC AC+V (N) (L)+VFG AC(N)AC(L)V.ADJCN1210Fig.5.7 Front view of option -R (PJMA1000F)CN1Fig.5.8 Front view of option -R (PJMA1500F)19Fig.5.9 Pin numberTable 5.5 Pin configuration and function of CN1PINFUNCTION1-:N.C.2-:N.C.3RC :Remote ON/OFF4RCG :Remote ON/OFF(GND)5-:N.C.6-:N.C.7-:N.C.8-:N.C.9-:N.C.10-:N.C.Table 5.6 Mating connectors and terminals on CN1ConnectorHousingTerminalMfrReel :SPHD-002T-P0.5CN1 S10B-PHDSS+VPHDR-10VS Loose :BPHD-001T-P0.5●?W (PJMA1000F, PJMA1500F):BPHD-002T-P0.5J.S.T.-The ?W option models provide remote sensing, low output voltagealarm (LV alarm), and parallel operation.-The appearance of the ?W option model is different from that ofthe standard mode. Contact us for more details.-Designated harnesses are available for sale. See Optional Parts.-The differences from the standard model are shown in Table 5.7.-PJMA1500F-48 does not support this option.Please contact us for any other conditions.-VV.ADJFGAC AC(N) (L)CN 1CN 2210210Fig.5.11 Front view of option -W (PJMA1500F)1919CN2Fig.5.12 Pin numberV.ADJTable 5.8 Pin configuration and function of CN1 and CN2PINFUNCTION1+M : Self sensing terminal (Don’twire for external function)2+S :+Sensing3-:N.C.4-:N.C.5LV:LV alarm6LVG :LV alarm (GND)7CB :Current balance8-:N.C.9-M : Self sensing terminal (Don’twire for external function)10-S:-SensingTable 5.9 Mating connectors and terminals on CN1 and CN2Connector Housing Terminal MfrReel :SPHD-002T-P0.5CN1CN2 S10B-PHDSS PHDR-10VS Loose :BPHD-001T-P0.5 J.S.T.:BPHD-002T-P0.5■LV alarmThe operating conditions of the LV alarm are shown in Table 5.10.The internal circuit of the LV alarm is shown in Fig. 5.13. The LValarm is isolated from input, output, and FG.0.1 F 100kW LVFig.5.13 LV internal circuitLVGPJMA-17Table 5.7 Specification differences of Option -WLoad regulationRippleRipple noise-VV.ADJ1.5 times of standard spec.1.5 times of standard spec.1.5 times of standard spec.CN1H-SN-31(install)FG AC AC+V (N) (L)CN2Fig.5.10 Front view of option -W (PJMA1000F)Table 5.10 LV alarm operating conditionsAlarmOutput of alarmIf the output voltage drops orOpen collector methodstops, the LV and LVG terminalsgive an alarm signal.Note : 1In case of overcurrent,the alarm signal will beLVunstable.2The alarm signal won’tbe given in paralleloperation if OR diodesare not used.May 09, 2025Good : Low(0 - 0.8V, 10mA max)Fail : High or Open50V 10mA max