title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
1165/1330

This page is the summary of page 1165 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

AC-DC Power Supplies Medical TypeInstruction Manual!Parallel operation is not possible.!Redundancy operation is available by wiring as shown below.!Even a slight difference in output voltage can affect the balancebetween the values of I1 and I2.Please make sure that the value of I3 does not exceed the ratedcurrent of a power supply.I3 [ the rated current value3 TemperatureMeasurement Point!Environment to use it and Installation environmentWhen using it,it is necessary to radiate heat by the heat of the powersupply.PowerSupplyPowerSupplyTable 3.1 - 3.4 shows the relation between the upper limit temperature(Point A and Point B) and load factors.Please consider the ventilation so that the convection which isenough for the whole power supply is provided.And temperature of Point A and Point B please become lower thanupper limit temperature.+-+-The life expectancy in the upper bound temperature (Point A andPoint B) is three years or more.I1I2Please refer to External View for the position of Point A and Point B.Remarks:*Please be careful of electric shock or earth leakage in case oftemperature measurement, because Point A and Point B is livepotential.I3LoadFig.2.2 Example of redundancy operationTable 3.1 Temperatures of Point A, Point B PMA15F-OMountingMax temperatureLoad factorMethodPoint A[C] Point B[C]70%