Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
AC-DC Power Supplies Enclosed TypeFETA7000TOrdering informationFET A 7000 T -OO1 2 3 4 5FETARExample recommended EMI/EMC filterTAC-30-6831 Series name2 Single output3 Output wattage4 Triple input phase5 Output voltage* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.MODELFETA7000T-48FETA7000T-144MAX OUTPUT WATTAGE[W]*171137488DC OUTPUT48V 148.2A144V 52ASPECIFICATIONSMODELFETA7000T-48FETA7000T-144VOLTAGE[V]AC170 - 264 3f (Output derating is required at AC170V - 180V. Refer to“Derating”)CURRENT[A]ACIN 200V22.7typ23.9typFREQUENCY[Hz]50 / 60 (47 - 63)INPUTEFFICIENCY[%]ACIN 230V90.5% (Io=100%)90.5% (Io=100%)POWER FACTORACIN 230V0.98typ (Io=100%)INRUSH CURRENT[A]ACIN 200V*230max / 60max (Primary inrush current /Secondary inrush current) (More than 10 sec. to re-start)LEAKAGE CURRENT[mA]3.0max (ACIN 240V 60Hz, Io=100%, According to IEC62368-1)VOLTAGE[V]48144CURRENT[A]ACIN 170V-180V Output derating is required at ACIN 180V or less (refer to“Derating”)ACIN 180V-264V 148.2 52LINE REGULATION[mV]192max360maxLOAD REGULATION[mV]960max1800maxRIPPLE[mVp-p]0 to +40C *3 480max 960maxRIPPLE NOISE[mVp-p]OUTPUT-10 to 0C *3 600max 1200maxTEMPERATURE REGULATION[mV]DRIFT[mV]*4192max384maxSTART-UP TIME[s]1.7max (ACIN 200V, Io=100%)HOLD-UP TIME[ms]ACIN 200V10typ (Io=100%)20typ (Io=50%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V] *528.8 - 52.8 *686.4 - 158.4 *7OUTPUT VOLTAGE SETTING[V]47 - 49141 - 147Works over 105% of rating (Recovers automatically, Hiccup overcurrent)OVERCURRENT PROTECTION(Output voltage shuts down when the output voltage continuously drops due to overcurrent protection.) *8PROTECTIONOVERVOLTAGE PROTECTION[V] *8 56 - 60 168 - 180CIRCUIT ANDDC_OK LAMPLED (Green)OTHERSALARM LAMPLED (Amber)REMOTE ON/OFFProvidedINPUT-OUTPUT-AUX-RC-WRN-PGAC3,000V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature)ISOLATIONOUTPUT-AUX-RC-WRN-PGAC100V 1minute, Cutoff current = 100mA, DC100V 50MW min (At room temperature)OPERATING TEMP.,HUMID.AND ALTITUDE-10 to +60C (Refer to“Derating”), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) maxENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each along X, Y and Z axisSAFETY ANDNOISE REGULATIONSOTHERSAGENCY APPROVALSUL62368-1, C-UL (CSA62368-1), EN62368-1CONDUCTED NOISEComplies with FCC Part15-A, CISPR32-A, EN55032-A, VCCI-AHARMONIC ATTENUATORComplies with IEC61000-3-12CASE SIZE/WEIGHT*9388X43X475mm [15.28X1.69X18.70 inches] (WXHXD) / 11kg maxCOOLING METHODForced cooling (internal fan)*1 AUX output power is not included.*2 The current of input surge to a built-in noise filter (0.2ms or less) is excluded.*3 Measured by 500MHz oscilloscope.Ripple and ripple noise is measured on measuring board with capacitor of 22mF within150mm from the output terminal.*4 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,with the input voltage held constant at the rated input/output.*5 Can't be used above the rated output current and the rated output power.*6 When the output voltage is adjusted to higher than 49.92V and the load factor is over 70%of the rated current, if the load current changes quickly (< 200msec), the output voltagedrops approximately 5V below the setting voltage.*7 When the output voltage is adjusted to higher than 149.82V and the load factor is over 70%of the rated current, if the load current changes quickly (<200msec), the output voltagedrops approximately 15V below the setting voltage.*8 Output voltage recovers from protection by shutting down the input voltage and waitingmore than 10 seconds then turning on AC input again, or turning off the output voltage byremote control.*9 Case size contains neither the terminal blocks, connector and screw.* To meet the specifications, do not operate over-loaded condition.* A sound may occur from power supply at peak loading.FETA-8? 120 ?