title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
126/916

This page is the summary of page 126 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

AC-DC Power Supplies Enclosed TypeFETA7000STOrdering informationFET A 7000 ST -OO1 2 3 4 5FETARExample recommended EMI/EMC filterYAC-25-6851 Series name2 Single output3 Output wattage4 3f 4-Wire5 Output voltage* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.MODELFETA7000ST-48FETA7000ST-144MAX OUTPUT WATTAGE[W]*171137488DC OUTPUT48V 148.2A144V 52ASPECIFICATIONSMODELFETA7000ST-48FETA7000ST-144VOLTAGE[V]AC300 - 480 3f4-Wire (Output derating is required at AC300V - 320V. Refer to“Derating”)CURRENT[A]ACIN 400V*211.4typ12.0typFREQUENCY[Hz]50 / 60 (47 - 63)INPUTEFFICIENCY[%]ACIN 400V90.5% (Io=100%)90.5% (Io=100%)POWER FACTORACIN 400V0.98typ (Io=100%)INRUSH CURRENT[A]ACIN 400V*340max / 80max (Primary inrush current /Secondary inrush current) (More than 10 sec. to re-start)LEAKAGE CURRENT[mA]5.0max (ACIN 480V 60Hz, Io=100%, According to IEC62368-1)VOLTAGE[V]48144CURRENT[A]ACIN 300V-320V Output derating is required at ACIN 320V or less (refer to“Derating”)ACIN 320V-480V 148.2 52LINE REGULATION[mV]192max360maxLOAD REGULATION[mV]960max1800maxRIPPLE[mVp-p]0 to +40C *4 480max 960maxRIPPLE NOISE[mVp-p]OUTPUT-10 to 0C *4 600max 1200maxTEMPERATURE REGULATION[mV]DRIFT[mV]*5192max384maxSTART-UP TIME[s]1.7max (ACIN 400V, Io=100%)HOLD-UP TIME[ms]ACIN 400V10typ (Io=100%)20typ (Io=50%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V] *628.8 - 52.8 *786.4 - 158.4 *8OUTPUT VOLTAGE SETTING[V]47 - 49141 - 147Works over 105% of rating (Recovers automatically, Hiccup overcurrent)OVERCURRENT PROTECTION(Output voltage shuts down when the output voltage continuously drops due to overcurrent protection.) *9PROTECTIONOVERVOLTAGE PROTECTION[V] *9 56 - 60 168 - 180CIRCUIT ANDDC_OK LAMPLED (Green)OTHERSALARM LAMPLED (Amber)REMOTE ON/OFFProvidedINPUT-OUTPUT-AUX-RC-WRN-PGAC3,000V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature)ISOLATIONOUTPUT-AUX-RC-WRN-PGAC100V 1minute, Cutoff current = 100mA, DC100V 50MW min (At room temperature)OPERATING TEMP.,HUMID.AND ALTITUDE-10 to +60C (Refer to“Derating”), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) maxENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each along X, Y and Z axisAGENCY APPROVALSUL62368-1, C-UL (CSA62368-1), EN62368-1SAFETY ANDNOISE REGULATIONSOTHERSCONDUCTED NOISEComplies with FCC Part15-A, CISPR32-A, EN55032-A, VCCI-A with an external EMI/EMC filter. (refer toInstruction manual)HARMONIC ATTENUATORComplies with IEC61000-3-2 Class A *10CASE SIZE/WEIGHT*11388X43X475mm [15.28X1.69X18.70 inches] (WXHXD) / 11kg maxCOOLING METHODForced cooling (internal fan)*1 AUX output power is not included.*2 The current flowing through the neutral line increases when AC input voltage is overAC456V 3f 4-Wire. The fl owing current will vary according to the input voltage and theload current. The maximum flowing current will be 18A.*3 The current of input surge to a built-in noise filter (0.2ms or less) is excluded.*4 Measured by 500MHz oscilloscope.Ripple and ripple noise is measured on measuring board with capacitor of 22mF within150mm from the output terminal.*5 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,with the input voltage held constant at the rated input/output.*6 Can't be used above the rated output current and the rated output power.*7 When the output voltage is adjusted to higher than 49.92V and the load factor is over 70%of the rated current, if the load current changes quickly (< 200msec), the output voltagedrops approximately 5V below the setting voltage.*8 When the output voltage is adjusted to higher than 149.82V and the load factor is over 70%of the rated current, if the load current changes quickly (<200msec), the output voltagedrops approximately 15V below the setting voltage.*9 Output voltage recovers from protection by shutting down the input voltage and waitingmore than 10 seconds then turning on AC input again, or turning off the output voltage byremote control.*10 Please contact us about another class.*11 Case size contains neither the terminal blocks, connector and screw.* To meet the specifications, do not operate over-loaded condition.* A sound may occur from power supply at peak loading.FETA-12? 124 ?