Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
AC-DC Power Supplies Enclosed TypeInstruction Manual!You can adjust the output voltage in parallel operation by adjustinga potentiometer of just one power supply.To do so, select one power supply as the master unit and turn thepotentiometers of the other (slave) power supplies clockwise tothe end.Once you have done this, you can adjust the output voltage byturning the potentiometer of the master unit.!If you use the remote sensing function in parallel operation, connectparallelly +S and -S of slave power supplies must be connectedto master and connect the sensing wire from the masterunit to the load.!You cannot parallelly operate power supplies with different outputvoltage or electrical power.!If an output stops (through the remote ON/OFF circuit or due toan input shutoff or failure) in parallel operation, the LED of thestopped unit lights off.!When the output current of one unit becomes 10% or less of therated current, the PG signals may turn”High”and the fan maystop.Install H-SN-19Install H-PA-3No.1(Master)V. ADJCN1AC AC( L) ( N) NC FGCN2!Hot-swap or Hot-plug is not available.!If 2 or more units failed, suffi cient power could not be provided tothe system. Therefore, please replace the failed unit immediatelyin case where unit failure is found.!If you have any questions about series, parallel and N+1 redundancyoperations, please contact us.4 TemperatureMeasurement Point!Standard for Cooling? PBA10F, PBA15F, PBW15F, PBA30F,PBW30F, PBA50F, PBW50F, PBA75F,PBA100F and PBA150F!Please make sure that the temperature of Point A (see ExternalView) falls under a temperature specifi ed in Table 4.1.!The temperatures shown in Table 4.1 for PBA10F, PBA15F,PBW15F, PBA30F and PBW30F are those for their capacitors.!Point A is engraved on the chassis of PBA50F, PBW50F, PBA75F,PBA100F and PBA150F.No.2(Slave)AC AC( L) ( N) NC FGRemove H-SN-19No.5(Slave)CN3V. ADJCN1CN2CN3V. ADJCN1AC AC( L) ( N) NC FGCN2LoadInstall H-PA-3Table 4.1 Temperatures of Point AModel NamePoint AAmbient Temperature: 50C Ambient Temperature: 71CPBA10F58C or less74C or lessPBA15F and PBW15F64C or less73C or lessPBA30F and PBW30F73C or less82C or lessPBA50F and PBW50F72C or less82C or lessPBA75F83C or less84C or lessPBA100F87C or less83C or lessPBA150F89C or less85C or lessCN3Fig.3.3 Example of parallel connection(PBA1500F)3.3 N+1 Parallel Redundancy Operation? PBA300F, PBA600F, PBA1000F, PBA1500Fand PBA1500T!You can have N+1 redundancy operation for improved system reliability.!If you add one extra power supply in parallel operation, even ifone of the power supplies in your system fails, the remaining nonfailedpower supplies continue to sustain the system. If one of thepower supplies stops operating, the output voltage may changeabout 5%.!When unit replacement is required due to unit failure, input voltagefor all units must be cut off.!After replacement, please make sure that all wirings are completedcorrectly, before re-applying input voltage.5 Life Expectancy andWarranty!Life ExpectancyPlease see the following tables for life expectancy.? PBA10F, PBA15F, PBW15F, PBA30F,PBW30F, PBA50F, PBW50F, PBA75F,PBA100F and PBA150FMountingAnnual Average ofMethodAmbient TemperaturesAB and CLoad Factor50% 100%Ta = 30C or less10 years or more10 years or moreTa = 40C10 years or more6 yearsTa = 50C9 years3 yearsTa = 20C or less10 years or more10 years or moreTa = 30C10 years or more6 yearsTa = 40C8 years3 yearsPBA/PBW-42