title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
146/916

This page is the summary of page 146 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

AC-DC Power Supplies Enclosed TypeSCHA 10000T/SCDA 10000TOrdering informationSC H A 10000 T -48 -1 2 3 4 5 6 7SCRExample recommended EMI/EMC filterFilter TAC-50-2231 Series name2 External formH:Wide front interfaceD:Compact front interface3 Single output4 Output wattage5 Three-phase input6 Output voltage7 Optional* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.SCHA10000TSCDA10000T*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.SPECIFICATIONSINPUTOUTPUTPROTECTIONCIRCUIT ANDOTHERSISOLATIONENVIRONMENTSAFETY ANDNOISEREGULATIONSOTHERSMODEL SCHA10000T-48 SCDA10000T-48VOLTAGE[V]CURRENT[A] ACIN200V 35typAC160 - 264 3fFREQUENCY[Hz] 50/60 (47 - 63)EFFICIENCY[%] ACIN200-240V 90typPOWER FACTOR ACIN200-240V 0.99typ (Io=100%)INRUSH CURRENT[A] ACIN240V *1LEAKAGE CURRENT[mA]VOLTAGE[V] 48CURRENT[A] 208WATTAGE[W] 9,984LINE REGULATION[mV]LOAD REGULATION[mV]60typ / 80typ (Primary inrush current /Secondary inrush current) (More than 3 sec. to re-start)5.0max (ACIN 240V 60Hz, Io=0 - 100%, According to IEC62368-1)192max720maxRIPPLE[mVp-p] 0 to +50C *2 150maxRIPPLE NOISE[mVp-p] 0 to +50C *2 200max (BW:500MHz)TEMPERATURE REGULATION[mV] 0 to +50C 240maxDRIFT[mV] *3 192maxSTART-UP TIME[ms] *6 750max (ACIN 200V, Io=100%)HOLD-UP TIME[ms]OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 43.2 - 52.820typ (ACIN200V, Io=100%)OUTPUT VOLTAGE SETTING[V]47.0 - 49.0OVERCURRENT PROTECTIONActivate over 105% - 120% of rated current and recovers automatically. (Shut down if low-voltage protection activated)OVERVOLTAGE PROTECTION[V]*456.0 - 59.0 (shut down)LOW-VOLTAGE PROTECTION[V]*428.8 - 33.6 (shut down)OPERATING INDICATIONLED : Green (48VDC output), White (AC IN)ALARM OUTPUTDetecting low input voltage, detecting open phase, detecting low output voltageREMOTE ON/OFF (SYSTEM ON/OFF)Provided(INPUT) - (OUTPUT-SYSTEM ON/OFF-REMOTE SIGNAL ON/OFF-ALARM)(INPUT) - (FG)AC3,000V 1minute, Cutoff current = 100mA, DC2,200V 1minute, Cutoff current = 1mA (At Room Temperature)DC500V 50MW min (At Room Temperature)AC2,000V 1minute, Cutoff current = 100mA, DC2,200V 1minute, Cutoff current = 1mA (At Room Temperature)DC500V 50MW min (At Room Temperature)(OUTPUT-SYSTEM ON/OFF-REMOTESIGNAL ON/OFF-ALARM) - (FG)AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)(OUTPUT) - (SYSTEM ON/OFF-REMOTEAC100V 1minute, Cutoff current = 50mA, DC100V 10MW min (At Room Temperature)SIGNAL ON/OFF-ALARM)OPERATING TEMP.,HUMID.AND ALTITUDE0 to +50C, 20 - 85%RH (Non condensing), 3,000m(10,000feet) max (Refer to Cooling method)STORAGE TEMP.,HUMID.AND ALTITUDE-25 to +85C, 20 - 90%RH (Non condensing), 9,000m(30,000feet) maxVIBRATION10 - 55Hz, 19.6m/s 2 (2G) , 3minutes period , 30 minutes each along X,Y and Z axisIMPACT196.1m/s 2 (20G), 11ms, once each along X, Y and Z axisAGENCY APPROVALSUL60950-1, C-UL (CSA60950-1), EN62368-1 compliesCONDUCTED NOISEComplies with EN55011 Group1-A, EN55022-A, CISPR22-A, FCC part15 classA, additional EMI/EMC Filter required for meeting class BHARMONIC ATTENUATORComplies with IEC61000-3-12CASE SIZE/WEIGHT*5459X150X320mm [18.07X5.91X12.6 inches] (WXHXD)/23kg max310.5X150X510mm [12.22X5.91X20.08 inches] (WXHXD)/20kg maxCOOLING METHODForced cooling (require external fan)*1The current of input surge to a built-in noise filter (0.2ms or less) is excluded.*2Measured by 500MHz oscilloscope.*3Drift is the change in DC output for an eight hour period after a half-hour warm-upat 25C, with the input voltage held constant at the rated input/output.*4To recover output voltage, recycle input voltage after 3 or more seconds.*5 Case size contains neither the terminal blocks, connector and screw nor.*6 When input voltage recycling is needed for output recovery, AC power shall be removedand cycled after 3 seconds to reset the protection circuit.Please contact us when it’s necessary to restart the power supply in less than 3 seconds.SC-2? 144 ?