title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
154/1330

This page is the summary of page 154 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

AC-DC Power Supplies Enclosed TypeInstruction Manual5 Ground-V!When installing the power supply, make sure the FG terminal andthe chassis (at more than 2 places) are connected to the safetyearth ground.+VCN3126 Options and Others6.1 Outline of Options? ?C-With the ?C option, the internal PCB has a conformal coating foranti-humidity.? ?G (PJA300F, PJA600F, PJA1000F, PJA1500F)-With the ?G option, the leakage current of the power supply isreduced.-The differences between the option ?G models and the standardmodels are shown below.Table 6.1 Low leakage current typePJA300F/600FPJA1000F/1500FLeakage Current(AC240V 60Hz)0.15mA max0.2mA maxConducted NoiseN/AOutput Ripple NoisePlease contact us for details aboutRipple Noise* This is the result of measurement of the testing board with capacitorsof 22μF and 0.1μF placed at 150 mm from the output terminalsby a 20 MHz oscilloscope or a ripple-noise meter equivalentto Keisoku-Giken RM103.? ?V (PJA300F, PJA600F, PJA1000F, PJA1500F)-With the ?V option, the power supply comes with an externalpotentiometer connector instead of a built-in potentiometer.-The appearance of the ?V models is different from that of thestandard models. Contact us for more details.-Note that if the power supply is turned on with CN3 open, theoutput voltage will make a big drop.CN3+V +V? ?RFig.6.2 Front view of option-V (PJA1500F)-The ?R option makes it possible to switch on or off the output byapplying voltage to the RC terminals of the power supply froman external power source.-The appearance of the option ?R models is different from that ofthe standard models.-Designated harnesses for the RC terminals are available forsale. See Optional Parts for more details.-The ?R option models have extra connectors. Please contact usfor more details.Table 6.2 Remote on/off operating conditionsModel NameBuilt-inResistorRi [ W ]Voltage between RCand RCG [V]Output ON Output OFFInputCurrent[mA]PJA100F, PJA150F,PJA300F, PJA600F,PJA1000F, PJA1500F7804.5 - 12.50 - 0.5(20max)External PowerSourceR *1Input CurrentSWRemote ON/OFF connector (Optional)RCRCGInside of a PowerSupplyFig.6.3 Example of using a remote ON/OFF circuit*1 If the external voltage applied to the RC terminals is 4.5-12.5V, the current limiting resistor is not necessary. If the voltageapplied is more than 12.5V, make sure the current limitingresistor R is used.The value of the current limiting resistor is obtained by the followingformula:R[W]= Vcc-(1.1+RiX0.005) Vcc : External Power Source0.005* Note that reversed connection damages internal components ofthe power supply.* The remote control circuit is isolated from input, output and FG.RiV.ADJFig.6.1 Front view of option-V (PJA600F)!Remote on/off control for PJA100F, PJA150F, and PJA300F-Remote control connectors are added. Contact us for more details.-Make sure there is an interval of more than 2 seconds in the on/off cycle. If the interval is shorter, the start-up time may becomelonger (approx. 2 seconds).PJA-22