COSEL Power Supply, Noise Filter 2025 Product Catalog
TECS-seriesMounting Area!The mounting screw should be M3. The hatched area shows the allowance of mounting area.CN16.7R3.56.76.7mounting area(primary side)6.7R3.5Unit〔mm〕mounting area(secondary side)TECS!The mounting area (primary side) must be insulated from areas that user accessible parts of the fi nal product, so if the enclosure is metaland the mounting components and spacers are metal, be careful to insulate them.!When installing, be careful to avoid contact with mounted components.!This product uses SMD technology. Please avoid the PCB installation method which includes the twisting stress or the bending stress.!Do not touch any SMD components on the unit and soldering points.Derating? Derating curve for input voltageLoad factor [%]1008085 90Input voltage [VAC]●TECS10FAmbient temperature derating curve atrated input (Reference value)10012 3 4●TECS20FAmbient temperature derating curve atrated input (Reference value)1001 2 3Load factor [%]8070605040200-20-10010203040506070808590Load factor [%]80706050402520150-20-10010203040506070808590Ambient temperature [C]Ambient temperature [C]Cooling methodConvectionForced air(0.5m 3 /min)Output voltageInstallation conditionA,B,C,D,E,F5V 112V,15V 224V 35V,12V,15V,24V 4!In case of forced air cooling, ventilation must be uniform.Cooling methodConvectionForced air(0.5m 3 /min)Output voltageInstallation conditionA,B,C,D,E,F5V 112V15V,24V 25V,12V,15V,24V 3!In case of forced air cooling, ventilation must be uniform.? 163 ?TECS-11