Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
TECS-series●TECS45F-NAmbient temperature derating curve atrated input (Reference value)Load factor [%]10080604030201 2 30-10010203040506070Ambient temperature [C]●TECS65F-NAmbient temperature derating curve atrated input (Reference value)Load factor [%]10080604030201 20-10010203035 40506070Ambient temperature [C]3TECSCooling methodConvectionForced air(0.5m 3 /min)Output voltageInstallation conditionA,B,C,D,E5V 112V 124V 25V,12V,24V 3!In case of forced air cooling, ventilation must be uniform.F-Cooling methodConvectionForced air(0.5m 3 /min)Output voltageInstallation conditionA,B,C,D,E5V 112V 124V 25V,12V,24V 3!In case of forced air cooling, ventilation must be uniform.F-Instruction Manual◆Please see catalog and instructionmanual before you use.Instruction Manualhttps://www.cosel.co.jp/redirect/catalog/en/TECS/Before using our producthttps://en.cosel.co.jp/technical/caution/index.htmlTECSNOTICEBasic Characteristics DataModelCircuit methodSwitchingfrequency[kHz]Inputcurrent [A]*1InrushcurrentprotectionPCB/PatternMaterialSinglesidedDoublesidedSeries/Paralleloperation availabilitySeriesoperationTECS10F Flyback converter 20 to 125 0.21 Thermistor FR-4 Yes Yes NoTECS20F Flyback converter 20 to 125 0.40 Thermistor FR-4 Yes Yes NoTECS45F Flyback converter 20 to 250 0.90 Thermistor FR-4 Yes Yes NoTECS65F Flyback converter 20 to 800 1.25 Thermistor FR-4 Multilayer Yes No*1 The value of input current is at ACIN 100V and rated load.Paralleloperation? 165 ?TECS-13