title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
199/916

This page is the summary of page 199 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

LHA-seriesDerating? LHA300F-12-SNYAmbient temperature derating curve(Reference value)? LHA300F-24-SNY, -48-SNYAmbient temperature derating curve(Reference value)(1)Emounting(1)A,B,C,Dmounting(2)A - Fmounting(1)D,Emounting(1)A,B,Cmounting(2)A - Fmounting100100Load factor [%]807060(1)Convection40(2)Forced air(0.5m 3 / min)20100-1001015203040506070Load factor [%]8070604020100-100(1)Convection(2)Forced air(0.5m 3 / min)102025303540506070LHAAmbient temperature [C]Ambient temperature [C]!The operating ambient temperature is different by with / without chassis cover or mounting position.!In the hatched area, the specifi cation of Ripple, Ripple Noise is different from other area.!The ambient temperature should be measured 5 to 10 cm away from the power supply so that it won’t be infl uenced by the heat from thepower supply.!Please make sure the maximum component temperature rise given in Instruction manual 3 is not exceeded.!Please contact us for more information about operating ambient temperature.Instruction Manuals◆Please see catalog and instructionmanual before you use.LHANOTICEInstruction ManualsBefore using our producthttps://www.cosel.co.jp/redirect/catalog/en/LHA/https://en.cosel.co.jp/technical/caution/index.htmlBasic Characteristics DataModelCircuit methodSwitchingfrequency[kHz] *1 *2Inputcurrent*3 [A]LHA10F Flyback converter 20 to 125 0.26InrushcurrentprotectionResistance*4MaterialPCB/PatternSinglesidedDoublesidedSeries/Paralleloperation availabilitySeriesoperationParalleloperationCEM-3 Yes - Yes NoLHA15F Flyback converter 20 to 125 0.35 Thermistor CEM-3 Yes - Yes NoLHA30F Flyback converter 30 to 130 0.62 Thermistor FR-4 - Yes Yes NoLHA50F Flyback converter 30 to 130 1.05 Thermistor FR-4 - Yes Yes NoLHA75FLHA100FLHA150FLHA300FActive filter15 to 300Flyback converter50 to 140Active filter15 to 300Flyback converter35 to 130Active filter15 to 300LLC resonant converter90 to 280Active filter15 to 300LLC resonant converter65 to 2000.9ThermistorFR-4-YesYesNo1.2ThermistorFR-4-YesYesNo1.8ThermistorFR-4-YesYesNo3.5ThermistorFR-4-YesYesNo*1 The value changes depending on input and load.*2 At light load, burst operation is performed to reduce input power. The switching frequency is changed by using condition. Please contact us for more details.*3 The value of input current is at ACIN 100V and rated load.*4 Resistance of the line filter.? 197 ?LHA-23