Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
AC-DC Power Supplies Open Frame/ Enclosed TypeLFP150FOrdering informationLF P 150 F -O -O1 2 3 4 5 6RExample recommended EMI/EMC filterNAC-04-472High voltage pulse noise type : NAP seriesLow leakage current type : NAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *1C : with CoatingG : Low leakage currentJ1 : VH(J.S.T.)connector typeR : with Remote ON/OFFR2 : with Remote ON/OFFS : with ChassisSN : with Chassis & coverLFPPlease refer to Instructionmanual 7.This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.MODELLFP150F-24-YLFP150F-36-YLFP150F-48-YMAX OUTPUT WATTAGE[W]*2151.2 (302.4)151.2 (302.4)153.6 (307.2)DC OUTPUT*224V 6.3A (12.6A)36V 4.2A (8.4A)48V 3.2A (6.4A)SPECIFICATIONSMODELLFP150F-24-YLFP150F-36-YLFP150F-48-YVOLTAGE[V]AC85 - 264 1f (Refer to“Derating”,Instruction Manual 1 and 3) *5CURRENT[A]FREQUENCY[Hz]50 / 60 (47 - 63)ACIN 100V 85.5typ (Io=100%) 85.5typ (Io=100%) 85.5typ (Io=100%)EFFICIENCY[%]INPUTACIN 200V 88.0typ (Io=100%) 88.0typ (Io=100%) 88.0typ (Io=100%)POWER FACTORACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C)INRUSH CURRENT[A]ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C)LEAKAGE CURRENT[mA]0.40 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC62368-1 and DEN-AN)VOLTAGE[V]243648CURRENT[A]*26.3 (Peak 12.6)4.2 (Peak 8.4)3.2 (Peak 6.4)LINE REGULATION[mV]*796max144max192maxLOAD REGULATION[mV]*7150max240max240maxRIPPLE[mVp-p]*30 to +50C 150max 250max 250maxRIPPLE NOISE[mVp-p]*3OUTPUT-10 - 0C 180max 300max 300maxTEMPERATURE REGULATION[mV]DRIFT[mV]*496max144max192maxSTART-UP TIME[ms]350typ (ACIN 100V, Io=100%)HOLD-UP TIME[ms]20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]21.60 to 27.5032.40 to 39.6039.60 to 52.80OUTPUT VOLTAGE SETTING[V]24.00 to 24.9636.00 to 37.4448.00 to 49.92OVERCURRENT PROTECTIONWorks over 101% of rating and recovers automaticallyPROTECTION OVERVOLTAGE PROTECTION[V]27.60 to 33.6041.40 to 50.4055.20 to 67.20CIRCUIT AND OPERATING INDICATIONNot providedOTHERSREMOTE SENSINGNot providedREMOTE ON/OFFOption (Refer to Instruction Manual 6)INPUT-OUTPUT . RC*6AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)ISOLATIONOUTPUT-RC*6AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (At Room Temperature)OPERATING TEMP.,HUMID.AND ALTITUDE *5-10 to +70C, 20 - 90%RH (Non condensing) (Refer to“Derating”,Instruction Manual 3), 3,000m (10,000feet) maxENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axisSAFETY ANDAGENCY APPROVALS (At only AC input)UL60950-1, C-UL (CSA60950-1), EN62368-1 Complies with DEN-ANNOISECONDUCTED NOISEComplies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-BREGULATIONSHARMONIC ATTENUATORComplies with IEC61000-3-2 (Class A) *8OTHERS*1 Specifi cation is changed at option, refer to Instruction Manual.*2 Peak loading for 10sec. And Duty 40% max, refer to InstructionManual 6. In detail.( ) means peak current. There is a possibility that an internaldevice is damaged when the specification is exceeded.*3 This is the value that measured on measuring board withcapacitor of 22mF at 150mm from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter(Equivalent to KEISOKU-GIKEN: RM103).*4 Drift is the change in DC output for an eight hour periodafter a half-hour warm-up at 25C, with the input voltageheld constant at the rated input/output.*5 Derating is required.*6 Applicable when remote control (optional) is added.*7 Please contact us about dynamic load and input response.*8 Please contact us about another class.* To meet the specifications. Do not operate over-loaded condition.* Parallel operation is not possible.* Derating is required when operated with chassis and cover.* Sound noise may be generated by power supply in case of pulse load.LFP-4? 202 ?