Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
AC-DC Power Supplies Enclosed TypeInstruction ManualTable 1.2 Specifi cations of remote ON/OFF (RC-RCG)Output voltageONOFFBetween RC and RCGL level (0 to 0.5V) or openH level (4.5 to 12.5V)Table 1.3 Specifi cations of remote ON/OFF (Case of Fig.1.3)Connection methodFig.1.3 (a)Fig.1.3 (b)Fig.1.3 (c)Power ONPower OFFBase pinRCGAUXGRCG, AUXG(a) (b) (c)12VtypRb=1kWAUX AUX AUXRi=780WRCRa*112VRi=780WRC12VRi=780WRCVcctyptypRCGAUXGSWExcept FETA3000BCRCGAUXGSWExcept FETA3000BCFig.1.3 Examples of connecting remote ON/OFF circuitRCGAUXG*1 If the output of an external power supply is within the range of4.5 - 12.5V, you do not need a current limiting resistor Ra. Ifthe output exceeds 12.5V, however, please connect the currentlimiting resistor Ra.To calculate a current limiting resistance value, please use thefollowing equation.Ra[W]=Vcc-(1.1+RiX0.005)0.0051.9 Isolation!When you run a Hi-Pot test as receiving inspection, gradually increasethe voltage to start. When you shut down, decrease thevoltage gradually by using a dial. Please avoid a Hi-Pot testerwith a timer because when the timer is turned ON or OFF, it maygenerate a voltage a few times higher than the applied voltage.SW1.10 Signal Output (LED/Warning/Alarm)!Functions of LED indicators and Output of Warning/Alarm areshown below. LED indicators and Output of Warning/Alarm aresignals to check the presence/absence of voltage at the outputterminal of a power supply and to detect warning/fault conditions.The timing of signals might be vary depending on input and loadconditions. Please evaluate thoroughly.Table 1.4 Description of LED indicatorLED indicatorConditionOutput voltageOFFInput power not presentOFFGreen - ONNormal conditionONGreen - BlinkingDC OFF by RC signalOFFAmber - BlinkingWarning condition(refer to Table.1.5)ONAmber - ONFault condition(refer to Table.1.6)OFFTable 1.5 Description of the WarningsWarningOutput of WarningThe WRN signals are“Low”Open collector methodwhen the power supply operatesGood : L levelWRNnormally.The signals turn“High”whenAC input voltage is out ofspecification* or DC outputvoltage is wrong (DC outputis out of voltage adjustmentrange) or fan fan alarm/termal( FETA2500BA,FETA3000BA,FETA3000BC :0 to 0.5V at 3mAFETA7000TFETA7000ST :0 to 0.5V at 10mA)warning is detected.Bad: H level or Open(35Vmax)* FETA7000STThis does not affect product quality. The current fl owing throughthe neutral line (N phase) increases when AC input voltage is overAC456V three phase four wire (18Amax). Select a suitable wiregauge for the neutral line.FETA-23