title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
216/916

This page is the summary of page 216 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

AC-DC Power Supplies Open Frame/ Enclosed TypeLFA15FOrdering informationLF A 15 F -O -O1 2 3 4 5 6RExample recommended EMI/EMC filterNAC-04-472High voltage pulse noise type : NAP seriesLow leakage current type : NAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 OptionalC : with CoatingG : Low leakage currentJ1 : VH(J.S.T.)connector typeS : with ChassisSN : with Chassis & coverY : with PotentiometerLFAThis power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.LFA-4Specification is changed atoption, refer to InstructionManual.MODELLFA15F-3R3-YLFA15F-5LFA15F-12LFA15F-15LFA15F-24MAX OUTPUT WATTAGE[W]9.91515.61516.8DC OUTPUT3.3V 3A5V 3A12V 1.3A15V 1A24V 0.7ASPECIFICATIONSMODELLFA15F-3R3-YLFA15F-5LFA15F-12LFA15F-15LFA15F-24VOLTAGE[V]AC85 - 264 1f (Refer to“Derating”, Instruction Manual 1 and 3) *3CURRENT[A]FREQUENCY[Hz]50 / 60 (47 - 440)INPUTACIN 100V 68.0typ 73.0typ 76.0typ 77.0typ 78.0typEFFICIENCY[%]ACIN 200V 69.0typ 76.0typ 78.5typ 80.0typ 81.5typINRUSH CURRENT[A]LEAKAGE CURRENT[mA]0.15/0.30max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC62368-1 and DEN-AN)VOLTAGE[V]3.35121524CURRENT[A]3.03.01.31.00.7LINE REGULATION[mV]*520max20max48max60max96maxLOAD REGULATION[mV]*540max40max100max120max150max0 to +50C80max80max120max120max120maxRIPPLE[mVp-p]-10 - 0C 140max 140max 160max 160max 160max*1Io=0 - 35% 190max 160max 240max 240max 280max0 to +50C120max120max150max150max150maxOUTPUTRIPPLE NOISE[mVp-p]-10 - 0C 160max 160max 180max 180max 180max*1Io=0 - 35% 240max 240max 300max 300max 320maxTEMPERATURE REGULATION[mV]DRIFT[mV]*220max20max48max60max96maxSTART-UP TIME[ms]200typ (ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.HOLD-UP TIME[ms]20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]2.85 to 3.63Fixed (“Y”option is available for adjusting output voltage between±10%)OUTPUT VOLTAGE SETTING[V]3.30 to 3.404.90 to 5.3011.50 to 12.5014.40 to 15.6023.00 to 25.00OVERCURRENT PROTECTIONWorks over 105% of rating and recovers automaticallyPROTECTIONCIRCUIT ANDOTHERSISOLATIONENVIRONMENTSAFETY ANDNOISEREGULATIONSOTHERSOVERVOLTAGE PROTECTION4.00 to 5.255.75 to 7.0013.80 to 16.8017.25 to 21.0027.60 to 33.60OPERATING INDICATIONNot providedREMOTE SENSINGNot providedREMOTE ON/OFFNot providedINPUT-OUTPUTAC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)INPUT-FGAC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)OUTPUT-FGAC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)OPERATING TEMP.,HUMID.AND ALTITUDE-10 to +70C, 20 - 90%RH (Non condensing) (Refer to“Derating”, Instruction Manual 3), 3,000m (10,000 feet) max *3STORAGE TEMP.,HUMID.AND ALTITUDE-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) maxVIBRATION10 - 55Hz, 19.6m/s 2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axisAGENCY APPROVALSUL60950-1, C-UL (CSA60950-1), EN62368-1 Complies with DEN-ANCONDUCTED NOISEComplies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-BHARMONIC ATTENUATORComplies with IEC61000-3-2 (Class A) *6 (Not built-in to active fi lter) *4CASE SIZE/WEIGHT50X22X87.5mm [1.97X0.87X3.44 inches] (WXHXD) / 80g max (with chassis & cover : 190g max)COOLING METHODConvection (Refer to“Derating”, Instruction Manual 3) *3*1 This is the value that measured on measuring board withcapacitor of 22mF at 150mm from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter(Equivalent to KEISOKU-GIKEN: RM103).A circuit reducing standby power is built in this unit.Therefore, the internal switch element is intermittentoperated, and the Ripple/Ripple Noise specification in loadfactor Io=0-35% is different.Please refer to the Instruction Manual 1.7.*2 Drift is the change in DC output for an eight hour period aftera half-hour warm-up at 25C, with the input voltage heldconstant at the rated input/output.*3 Derating is required.*4 When two or more units are operating it may not comply withthe IEC61000-3-2.? 214 ?Please contact us for details.*5 Please contact us about dynamic load and input response.*6 Please contact us about another class.* To meet the specifications. Do not operate over-loaded condition.* Parallel operation is not possible.* Derating is required when operated with chassis and cover.* Sound noise may be generated by power supply in case of pulseload.