title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
226/916

This page is the summary of page 226 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

AC-DC Power Supplies Open Frame/ Enclosed TypeLFA150FOrdering informationLF A 150 F -O -O1 2 3 4 5 6LFALFA-14RThis power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *1C : with CoatingG : Low leakage currentH : with the function to be acceptableto output peak current (only 24V)J1 : VH(J.S.T.)connector typeR : with Remote ON/OFFR2 : with Remote ON/OFFS : with ChassisSN : with Chassis & coverY : with PotentiometerPlease refer to Instructionmanual 6.MODELLFA150F-3R3-YLFA150F-5-YLFA150F-12LFA150F-15LFA150F-24LFA150F-24-HLFA150F-36LFA150F-48MAX OUTPUT WATTAGE[W]*599150150150151.2151.2 (189.6)151.2153.6DC OUTPUT*53.3V 30A5V 30A12V 12.5A15V 10A24V 6.3A24V 6.3 (7.9)A 36V 4.2A48V 3.2ASPECIFICATIONSINPUTOUTPUTPROTECTIONCIRCUIT ANDOTHERSMODELLFA150F-3R3-YLFA150F-5-YLFA150F-12LFA150F-15LFA150F-24LFA150F-24-HLFA150F-36LFA150F-48VOLTAGE[V]AC85 - 264 1f (Refer to“Derating”, Instruction Manual 1 and 3) *4CURRENT[A]FREQUENCY[Hz]50 / 60 (47 - 63)EFFICIENCY[%]ACIN 100V 0.98typ 0.99typPOWER FACTOR (Io=100%)ACIN 200V 0.92typ 0.95typACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C)INRUSH CURRENT[A]ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C)LEAKAGE CURRENT[mA]0.40 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC62368-1 and DEN-AN)VOLTAGE[V]3.35121524243648CURRENT[A]*5303012.5106.36.3 (Peak 7.9)4.23.2LINE REGULATION[mV]*720max20max48max60max96max96max144max192maxLOAD REGULATION[mV]*740max40max100max120max150max150max240max240maxRIPPLE[mVp-p]RIPPLE NOISE[mVp-p]TEMPERATURE REGULATION[mV]DRIFT[mV]*320max20max48max60max96max96max144max192maxSTART-UP TIME[ms]350typ (ACIN 100V, Io=100%)HOLD-UP TIME[ms]20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]2.85 to 3.634.50 to 5.50Fixed (“Y”option is available for adjusting output voltage)OUTPUT VOLTAGE SETTING[V]3.30 to 3.405.00 to 5.1511.50 to 12.5014.40 to 15.6023.00 to 25.0023.00 to 25.0034.50 to 37.5046.00 to 50.00OVERCURRENT PROTECTIONWorks over 105% of rating (works over 101% of peak current at option -H) and recovers automaticallyOVERVOLTAGE PROTECTION4.00 to 5.255.75 to 7.0013.80 to 16.8017.25 to 21.0027.60 to 33.6027.60 to 33.6041.40 to 50.4055.20 to 67.20OPERATING INDICATIONNot providedREMOTE SENSINGNot providedREMOTE ON/OFFOption (Refer to Instruction Manual)INPUT-OUTPUT . RC*6AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)ISOLATIONOUTPUT-RC*6AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (At Room Temperature)OPERATING TEMP.,HUMID.AND ALTITUDE *4-10 to +70C, 20 - 90%RH (Non condensing) (Refer to“Derating”, Instruction Manual 3), 3,000m (10,000feet) maxENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axisSAFETY ANDAGENCY APPROVALSUL60950-1, C-UL (CSA60950-1), EN62368-1 Complies with DEN-ANNOISECONDUCTED NOISEComplies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-BREGULATIONSHARMONIC ATTENUATORComplies with IEC61000-3-2 (Class A) *8OTHERS*1 Specification is changeed at option, refer to Instruction Manual.*2 This is the value that measured on measuring board withcapacitor of 22mF at 150mm from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter(Equivalent to KEISOKU-GIKEN: RM103).*3 Drift is the change in DC output for an eight hour period after ahalf-hour warm-up at 25C, with the input voltage held constantat the rated input/output.*4 Derating is required.*5 ( ) means peak current. There is a possibility that an internaldevice is damaged when the specification is exceeded. Pleasecontact us about the detail.*6 Applicable when remote control (optional) is added.*7 Please contact us about dynamic load and input response.? 224 ?Example recommended EMI/EMC filterNAC-04-472High voltage pulse noise type : NAP seriesLow leakage current type : NAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.*8 Please contact us about another class.* To meet the specifications. Do not operate over-loadedcondition.* Parallel operation is not possible.* Derating is required when operated with chassis and cover.* Sound noise may be generated by power supply in case ofpulse load.