Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
AC-DC Power Supplies Open Frame/ Enclosed TypeLFA240FOrdering informationLF A 240 F -O -O1 2 3 4 5 6LFALFA-16RThis power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.MODELLFA240F-24LFA240F-24-HLFA240F-36LFA240F-48MAX OUTPUT WATTAGE[W]*5240240 (300)241.2240DC OUTPUT*524V 10A24V 10 (12.5)A36V 6.7A48V 5ASPECIFICATIONSINPUTOUTPUTPROTECTIONCIRCUIT ANDOTHERS1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *1C : with CoatingG : Low leakage currentH : with the function to be acceptableto output peak current (only 24V)J1 : VH(J.S.T.)connector typeR : with Remote ON/OFFR2 : with Remote ON/OFFS : with ChassisSN : with Chassis & coverT : Vertical terminal blockY : with PotentiometerPlease refer to Instructionmanual 6.MODELLFA240F-24LFA240F-24-HLFA240F-36LFA240F-48VOLTAGE[V]AC85 - 264 1f (Refer to“Derating”, Instruction Manual 1 and 3) *4CURRENT[A]FREQUENCY[Hz]50 / 60 (47 - 63)EFFICIENCY[%]ACIN 100VPOWER FACTOR (Io=100%) 0.99typACIN 200V 0.95typACIN 100V 15 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3 sec. to re-start)INRUSH CURRENT[A]ACIN 200V 30 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3 sec. to re-start)LEAKAGE CURRENT[mA]0.40 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC62368-1 and DEN-AN)VOLTAGE[V]24243648CURRENT[A]*51010 (Peak12.5)6.75LINE REGULATION[mV]*796max96max144max192maxLOAD REGULATION[mV]*7150max150max240max240maxRIPPLE[mVp-p]RIPPLE NOISE[mVp-p]TEMPERATURE REGULATION[mV]DRIFT[mV]*396max96max144max192maxSTART-UP TIME[ms]350typ (ACIN 100V, Io=100%)HOLD-UP TIME[ms]20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]Fixed (“Y”option is available for adjusting output voltage)OUTPUT VOLTAGE SETTING[V]23.00 to 25.0023.00 to 25.0034.50 to 37.5046.00 to 50.00OVERCURRENT PROTECTIONWorks over 105% of rating (works over 101% of peak current at option -H) and recovers automaticallyOVERVOLTAGE PROTECTION27.60 to 33.6027.60 to 33.6041.40 to 50.4055.20 to 67.20OPERATING INDICATIONNot providedREMOTE SENSINGNot providedREMOTE ON/OFFOption (Refer to Instruction Manual)INPUT-OUTPUT . RC*6AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)ISOLATIONOUTPUT-RC*6AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (At Room Temperature)OPERATING TEMP.,HUMID.AND ALTITUDE *4-10 to +70C, 20 - 90%RH (Non condensing) (Refer to“Derating”, Instruction Manual 3), 3,000m (10,000feet) maxENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axisSAFETY ANDAGENCY APPROVALSUL60950-1, C-UL (CSA60950-1), EN62368-1 Complies with DEN-ANNOISECONDUCTED NOISEComplies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-BREGULATIONSHARMONIC ATTENUATORComplies with IEC61000-3-2 (Class A) *8OTHERS*1 Specification is changeed at option, refer to Instruction Manual.*2 This is the value that measured on measuring board withcapacitor of 22mF at 150mm from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter(Equivalent to KEISOKU-GIKEN: RM103).*3 Drift is the change in DC output for an eight hour period after ahalf-hour warm-up at 25C, with the input voltage held constantat the rated input/output.*4 Derating is required.*5 ( ) means peak current. There is a possibility that an internaldevice is damaged when the specification is exceeded. Pleasecontact us about the detail.*6 Applicable when remote control (optional) is added.*7 Please contact us about dynamic load and input response.? 226 ?Example recommended EMI/EMC filterNAC-06-472High voltage pulse noise type : NAP seriesLow leakage current type : NAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.*8 Please contact us about another class.* To meet the specifications. Do not operate over-loadedcondition.* Parallel operation is not possible.* Derating is required when operated with chassis and cover.* Sound noise may be generated by power supply in case ofpulse load.