title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
234/916

This page is the summary of page 234 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

LFA-seriesLFADerating? LFA150F Ambient temperature derating curve(Reference value)Load factor [%]1008070604030201 (C)mounting1 (D), (E), (F)mounting1Convection2Forced air (0.5m 3 /min)1 (B)mounting1 (A)mounting0-100102025303540455055606570Ambient temperature [C]2 (A) ~ (F)mounting? LFA240F Ambient temperature derating curve(Reference value)Load factor [%]100801 (D), (F)mounting 1 (C)mounting 1 (B)mounting1 (E)mounting1 (A)mounting2 (A) ~ (F)mounting601Convection402Forced air (0.5m 3 /min)252 00-1001015203040506070Ambient temperature [C]? LFA300F Ambient temperature derating curve(Reference value)Load factor [%]10080605040201 (E), (F)mounting 1 (B), (C)mounting1 (D)mounting 1 (A)mounting1Convection2Forced air(1.0m 3 /min) :3.3V/5V/12V/15V(0.5m 3 /min) :24V/30V/36V/48V0-1001020253040506070Ambient temperature [C]OutputOutput power[W]voltage1Convection2Forced air3.3V132.0198.05V200.0300.012V204.0324.015V210.0330.024V300.0336.030V300.0330.036V302.4338.448V302.4336.02 (A) ~ (F)mounting? LFA150F-O-SN Ambient temperature deratingcurve (Reference value)Load factor [%]100807060504030201 (C)mounting 1 (B)mounting1 (D), (E)mounting1 (A)mounting2 (A) ~ (F)mounting1Convection2Forced air (0.5m 3 /min)0-100510202530404550Ambient temperature [C]? LFA240F-O-SN Ambient temperature deratingcurve (Reference value)Load factor [%]1 (D)mounting1 (E)mounting1 (C)mounting551 (B)mounting1 (A)mounting100802 (A) ~ (F)mounting7060401Convection2Forced air (0.5m 3 /min)2520100-10051015202530405060Ambient temperature [C]!The operative ambient temperature is different by with / without chassis cover or mounting position.Note: In the hatched area, the specifi cation of Ripple, Ripple Noise is different from other area.!Make sure the temperature at point A and point B is less than the temperatures shown in Instruction Manual 3.!The ambient temperature should be measured 5 to 10 cm away from the power supply so that it won’t be infl uenced by the heat from thepower supply. Please consult us for more details.Instruction Manual◆It is neccessary to read the“Instruction Manual”and“Before using our product”before you use our product.LFANOTICEInstruction ManualBefore using our produchttps://www.cosel.co.jp/redirect/catalog/en/LFA/https://en.cosel.co.jp/technical/caution/index.htmlLFA-22? 232 ?