Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
TB1INPUT180-240VAC3f39ARSTFG180-240VACREMOTESIGNALON/OFFPARALLELOPERATIONSIGNALSYSTEMON/OFFALMMONITOR48VDC(X)(X)(X)(X)(Y)CN1CN3CN5CN7CN9REMOTE SI GNAL ON1 2 3 4(X)(X)(X)(X)(Y)CN2CN4CN6CN8CN10V.ADJHOUTPUT(A) 48VDC TOTAL 208A20A1(X) (X) (X) (X) (X) (X) (X) (X) (X) (X)20A1120A220A1220A320A1320A420A520A 20A 20A20A20A14 15 16 17 1820A 20A 20A8 9 10(X) (X)(X)(X)(X)(X) (X)(X)(X)(X)20A6OUTPUT(B) 48VDC TOTAL 208A20A720A1920A20AC-DC Power Supplies Enclosed TypeInstruction Manual1.11 Parallel Control (Start in / out)!By connecting PCNT pin, difference of start-up voltage and stopvoltage can be prevented.!Total number of units should be no more than 10 units.1.12 Sequence Diagram1System ON / OFF is Short (Low) before turning on AC.ONINPUT ACOUTPUT 48VDCSignal inhibit timeONSYSTEM ON/OFFREMOTE 1SIGNALON/OFF 234ALARM ALMt dt rt 1t 2t 3t 4t 52System ON / OFF is Short (Low) after turned on AC.INPUT ACOUTPUT 48VDCSignal inhibit timeSYSTEM ON/OFFREMOTE 1SIGNALON/OFF 234ALARM ALMONt 1t 2t 12t rt 6Fig.1.7 Timing diagram 1ONt 4t 5t 6Fig.1.8 Timing diagram 2t 7OFFt 8t 7OFFt 8t 9t 9t 11t 10t 10t 11t ft fOFFOFF*t 12 : 48V turns on within 100ms after turned Short (Low) SystemON/OFF. Then the Remote signal ON/OFF 1 turns Low.*With shorted output condition, the output voltage will shut off andsend out the alarm.*In parallel, both output are synchronized ON/OFF with PCNT connectionbetween both.2 Single / Parallel / SeriesOperation2.1 Single Operation? SCHA10000T!OUTPUT(A) and OUTPUT(B), both are able to draw output currentup to 208 amps in total.!Fuses are built-in, and connected to each connector as shown inFig.2.2.!OUTPUT(B) has 20 amps drawing capability per each connector.!Internal output fuse may open with over current.To repair the opened fuse, please return the unit to us with a Coselissued RMA.OUTPUT(A)OUTPUT(B)3Abnormal conditionnormal conditionONINPUT ACOUTPUT 48VDCSignal inhibit timeSYSTEM ON/OFFREMOTESIGNALON/OFFALARM1234ONt fOccurringabnormalconditioninput voltageshut downt 13OFFOFFONFig.1.9 Timing diagram 3t 1input voltaget 2turn on againt 12t rt 4ONt 5t 6Fig.2.1 Output of SCHA10000Tinternal moduleinternal moduleinternal module20 Fuses(30A)fuses are connected to the +V(There is no fuse in -V)20 connectorsOUTPUT(B)t r : Rise time30ms max (DC48V External Capacity is less than 50,000μF, at rated load)70ms max (DC48V External Capacity is less than 150,000μF, at rated load)t d +t r : Start-up time 750ms maxt f : Fall time 500ms max (Load factor more than 10% )t 1 Signal inhibit time : 0.75 - 1.15st 2 : 100ms min t 4 -t 6 ,t 8 -t 11 : 0.6s±10%t 3 ,t 7 ,t 12 : 100ms max t 13 : 3s min*Remote signal ON/OFF sequence follows 1 if System ON/OFF isturned Short (Low) during inhibit time.SC-13Output terminal blockOUTPUT (A)Fig.2.2 Output part block diagram? SCDA10000T!Output connectors are able to draw output current up to 208 ampsin total.!Fuses are built-in, and connected to each connectors as shown inFig.2.4.!Output connectors has 20 amps drawing capability per each connector.