title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
252/916

This page is the summary of page 252 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

AC-DC Power Supplies PCB Mount TypeTEPS10FOrdering informationTEP S 10 F OO -O1 2 3 4 5 6Rwith Cover(option : -N)Example recommended EMI/EMC filterEAM-03-000High voltage pulse noise type : EAP series150KHz-1MHz (To safety ground the secondaryside) : EAC serie* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *1E2: Low leakage currentH : with output peak current(12V,24V)N : with coverFor option details, refer toInstruction Manual 8.TEPSStandard typeClassⅡThis power supply is manufactured by SMD technology. The stress to PCB like twisting or bending causes the defect of the unit, so handle the unit with care.*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.MODELTEPS10F05TEPS10F12TEPS10F12-HTEPS10F15TEPS10F24TEPS10F24-HMAX OUTPUT WATTAGE[W]*210.010.210.2 (15.0)10.510.810.8 (15.6)DC OUTPUT*25V 2.0A12V 0.85A12V 0.85 (1.25)A15V 0.7A24V 0.45A24V 0.45 (0.65)ASPECIFICATIONSMODELTEPS10F05TEPS10F12TEPS10F12-HTEPS10F15TEPS10F24TEPS10F24-HVOLTAGE[VAC]*285 - 264 1f(Refer to“Derating”and Instruction Manual 3.1)CURRENT[A]FREQUENCY[Hz]50 / 60 (45 - 440)INPUTACIN 100V 82.5typ 88.0typ 88.0typ 88.0typ 90.0typ 90.0typEFFICIENCY[%]ACIN 230V 84.0typ 88.0typ 88.0typ 88.0typ 90.0typ 90.0typACIN 100V 15typ (Io=100%) Ta=25C at cold startINRUSH CURRENT[A]ACIN 230V 35typ (Io=100%) Ta=25C at cold startLEAKAGE CURRENT[mA]0.1max (ACIN 264V, 60Hz, Io=100%, According to IEC62368-1, and DEN-AN)VOLTAGE[V]51212152424CURRENT[A]*22.00.850.85 (Peak 1.25)0.70.450.45 (Peak 0.65)LINE REGULATION[mV]*320max48max48max60max96max96maxLOAD REGULATION[mV]*340max100max100max120max150max150maxRIPPLE[mVp-p]*4 -20 to +60C200max200max200max200max200max200maxRIPPLE NOISE[mVp-p] *4 -20 to +60C 240max 240max 240max 240max 240max 240maxOUTPUT0 to +60C 50max 120max 120max 150max 240max 240maxTEMPERATURE REGULATION[mV]-20 to +60C 60max 160max 160max 200max 320max 320maxDRIFT[mV]*520max48max48max60max96max96maxSTART-UP TIME[ms]80typ (ACIN 100/230V, Io=100%)HOLD-UP TIME[ms]15typ (ACIN 100V, Io=100%) / 110typ (ACIN 230V, Io=100%)OUTPUT VOLTAGE SETTING[V]4.90 to 5.3011.50 to 12.5011.50 to 12.5014.50 to 15.5023.00 to 25.0023.00 to 25.00OVERCURRENT PROTECTION Works over 105% of rating (works over 101% of peak current at option -H) and recovers automaticallyPROTECTIONOVERVOLTAGE PROTECTION[V] 5.75 to 7.00 13.80 to 16.80 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 27.60 to 33.60CIRCUIT ANDOPERATING INDICATION Not providedOTHERSREMOTE SENSING Not providedISOLATIONINPUT-OUTPUT3,000VAC 1minute, Cutoff current = 10mA, 500VDC 100MW min (At Room Temperature)OPERATING TEMP.,HUMID.AND ALTITUDE *2-20 to +85C, 20 - 90%RH (Non condensing), (Refer to“Derating”), 5,000m (16,500feet) maxENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axisSAFETY ANDAGENCY APPROVALSUL62368-1, C-UL (equivalent to CAN/CSA-C22.2No.62368-1), EN62368-1, Complies with DEN-ANNOISECONDUCTED NOISE*6Complies with CISPR11-B, CISPR32-B, EN55011-B, EN55032-B, FCC Part 15-B, FCC Part 18-B, VCCI-BREGULATIONSHARMONIC ATTENUATOR *7Complies with IEC61000-3-2 (Class A) (No built-in power factor correction)OTHERS*1The listed options may affect the published standard specifications. Please contact us for detailed product specifications.*2Derating is required. ( ) means peak current. There is a possibility that an internal device is damaged when the specification is exceeded. Please contact us about the detail.*3At low load conditions, the burst mode operation will start. To check load regulation, you will need to measure the characteristics at average mode with instruments.*4This is the value that measured on measuring board with capacitor of 22mF and 0.1mF at 50mm from output terminal. (Refer to Instruction Manual)*5Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.*6When secondary circuit will be connected to earth, the spec will be changed. (Refer to Instruction Manual 2)*7Please contact us about another class. When two or more units are operating it may not comply with the IEC61000-3-2. Please contact us for details.*To meet the specification, do not operate overload condition.*Parallel operation is not possible.*Sound noise may be emitted from the power supply depending on operating conditions.TEPS-2? 250 ?