title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
34/916

This page is the summary of page 34 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

PDAAC-DC Power Supplies Enclosed TypePDA30FOrdering informationPD A 30 F -O -O1 2 3 4 5 6RExample recommended EMI/EMC filterNAC-06-472High voltage pulse noise type : NAP seriesLow leakage current type : NAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *1C: with CoatingN : with coverFor option details, refer toInstruction Manual 8.1.*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.MODELPDA30F-5PDA30F-12PDA30F-24MAX OUTPUT WATTAGE[W]*2303031.2DC OUTPUT*25V 6A12V 2.5A24V 1.3ASPECIFICATIONSMODELPDA30F-5PDA30F-12PDA30F-24VOLTAGE[VAC]*285 - 264 1f(Refer to“Derating”and Instruction Manual 1.1)CURRENT[A]FREQUENCY[Hz]50 / 60 (45 - 440)INPUTACIN 100V 83.0typ 82.0typ 83.5typEFFICIENCY[%]ACIN 230V 87.0typ 85.5typ 86.5typACIN 100V 15typ (Io=100%) at cold startINRUSH CURRENT[A]ACIN 230V 35typ (Io=100%) at cold startLEAKAGE CURRENT[mA]0.25 / 0.55 max (ACIN 100V / 240V, 60Hz, Io=100%, According to IEC62368-1, and DEN-AN)VOLTAGE[V]51224CURRENT[A]*26.02.51.3LINE REGULATION[mV]*320max48max96maxLOAD REGULATION[mV]*340max100max150maxRIPPLE[mVp-p]OUTPUT0 to +55C 120max 150max 150maxRIPPLE NOISE[mVp-p]-20 to 0C 160max 180max 180max*4Io=0 to 15%360max360max360maxTEMPERATURE REGULATION[mV]0 to +55C 50max 120max 240max-20 to +55C 60max 150max 290maxDRIFT[mV]*520max48max96maxSTART-UP TIME[ms]80typ (ACIN 100V, Io=100%)HOLD-UP TIME[ms]20typ (ACIN 100V, Io=100%) / 150typ (ACIN 230V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]4.50 to 5.5010.0 to 13.220.4 to 27.0OUTPUT VOLTAGE SETTING[V]5.00 to 5.1512.00 to 12.4824.00 to 24.96PROTECTION OVERCURRENT PROTECTIONWorks over 105% of rating and recovers automaticallyCIRCUIT AND OVERVOLTAGE PROTECTION5.75 to 7.0015.0 to 18.030.0 to 37.0OTHERSREMOTE SENSINGNot providedINPUT-OUTPUT3,000VAC 1minute, Cutoff current = 10mA, 500VDC 100MW min (At Room Temperature)ISOLATIONINPUT-FG2,000VAC 1minute, Cutoff current = 10mA, 500VDC 100MW min (At Room Temperature)OUTPUT-FG500VAC 1minute, Cutoff current = 25mA, 500VDC 100MW min (At Room Temperature)OPERATING TEMP.,HUMID.AND ALTITUDE *2-20 to +70C, 20 - 90%RH (Non condensing), 5,000m (16,500feet) maxENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axisSAFETY ANDAGENCY APPROVALSUL62368-1, C-UL (equivalent to CAN/CSA-C22.2No.62368-1), EN62368-1, Complies with DEN-ANNOISECONDUCTED NOISEComplies with CISPR11-B, CISPR32-B, EN55011-B, EN55032-B, FCC Part15-B, FCC Part18-B, VCCI-BREGULATIONSHARMONIC ATTENUATOR *6Complies with IEC61000-3-2 (Class A) (No built-in power factor correction)OTHERS*1 The listed options may affect the published standard specifications. Please contact us fordetailed product specifications.*2 Derating is required.Please contact us for DC input.*3 At low load conditions, the burst mode operation will start. To check load regulation, you willneed to measure the characteristics at average mode with instruments.*4 This is the value that measured on measuring board with capacitor of 22mF at 150mm fromoutput terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter(Equivalent to KEISOKU-GIKEN:RM104).Ripple and ripple noise spec is change at Io=0 to 15% by burst operation.*5 Drift is the change in DC output for an eight hour period after a half-hour warm-up at25C, with the input voltage held constant at the rated input/output.*6 Please contact us about another class. When two or more units are operating it maynot comply with the IEC61000-3-2. Please contact us for details.* To meet the specification, do not operate overload condition.* Parallel operation is not possible.* Sound noise may be generated by power supply in case of pulse load.PDA-4? 32 ?