Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
AC-DC Power Supplies Open Frame/ Enclosed TypeLFP150FOrdering informationLF P 150 F -O -O1 2 3 4 5 6RExample recommended EMI/EMC filterNAC-04-472High voltage pulse noise type : NAP seriesLow leakage current type : NAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *1C : with CoatingG : Low leakage currentJ1 : VH(J.S.T.)connector typeR : with Remote ON/OFFR2 : with Remote ON/OFFS : with ChassisSN : with Chassis & coverThis power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.MODELLFP150F-24-YLFP150F-36-YLFP150F-48-YMAX OUTPUT WATTAGE[W]*2151.2 (302.4)151.2 (302.4)153.6 (307.2)DC OUTPUT*224V 6.3A (12.6A)36V 4.2A (8.4A)48V 3.2A (6.4A)SPECIFICATIONSPlease refer to Instructionmanual 7.MODELLFP150F-24-YLFP150F-36-YLFP150F-48-YVOLTAGE[V]AC85 - 264 1f (Refer to“Derating”,Instruction Manual 1 and 3) *5CURRENT[A]FREQUENCY[Hz]50 / 60 (47 - 63)ACIN 100V 85.5typ (Io=100%) 85.5typ (Io=100%) 85.5typ (Io=100%)EFFICIENCY[%]INPUTACIN 200V 88.0typ (Io=100%) 88.0typ (Io=100%) 88.0typ (Io=100%)POWER FACTORACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C)INRUSH CURRENT[A]ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C)LEAKAGE CURRENT[mA]0.40 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC62368-1 and DEN-AN)VOLTAGE[V]243648CURRENT[A]*26.3 (Peak 12.6)4.2 (Peak 8.4)3.2 (Peak 6.4)LINE REGULATION[mV]*796max144max192maxLOAD REGULATION[mV]*7150max240max240maxRIPPLE[mVp-p]*30 to +50C 150max 250max 250maxRIPPLE NOISE[mVp-p]*3OUTPUT-10 - 0C 180max 300max 300maxTEMPERATURE REGULATION[mV]DRIFT[mV]*496max144max192maxSTART-UP TIME[ms]350typ (ACIN 100V, Io=100%)HOLD-UP TIME[ms]20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]21.60 to 27.5032.40 to 39.6039.60 to 52.80OUTPUT VOLTAGE SETTING[V]24.00 to 24.9636.00 to 37.4448.00 to 49.92OVERCURRENT PROTECTIONWorks over 101% of rating and recovers automaticallyPROTECTION OVERVOLTAGE PROTECTION[V]27.60 to 33.6041.40 to 50.4055.20 to 67.20CIRCUIT AND OPERATING INDICATIONNot providedOTHERSREMOTE SENSINGNot providedREMOTE ON/OFFOption (Refer to Instruction Manual 6)INPUT-OUTPUT . RC*6AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)ISOLATIONOUTPUT-RC*6AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (At Room Temperature)OPERATING TEMP.,HUMID.AND ALTITUDE *5-10 to +70C, 20 - 90%RH (Non condensing) (Refer to“Derating”,Instruction Manual 3), 3,000m (10,000feet) maxENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axisSAFETY ANDAGENCY APPROVALS (At only AC input)UL60950-1, C-UL (CSA60950-1), EN62368-1 Complies with DEN-ANNOISECONDUCTED NOISEComplies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-BREGULATIONSHARMONIC ATTENUATORComplies with IEC61000-3-2 (Class A) *8OTHERS*1 Specifi cation is changed at option, refer to Instruction Manual.*2 Peak loading for 10sec. And Duty 40% max, refer to InstructionManual 6. In detail.( ) means peak current. There is a possibility that an internaldevice is damaged when the specification is exceeded.*3 This is the value that measured on measuring board withcapacitor of 22mF at 150mm from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter(Equivalent to KEISOKU-GIKEN: RM103).*4 Drift is the change in DC output for an eight hour periodafter a half-hour warm-up at 25C, with the input voltageheld constant at the rated input/output.*5 Derating is required.*6 Applicable when remote control (optional) is added.*7 Please contact us about dynamic load and input response.*8 Please contact us about another class.* To meet the specifications. Do not operate over-loaded condition.* Parallel operation is not possible.* Derating is required when operated with chassis and cover.* Sound noise may be generated by power supply in case of pulse load.LFP-4