COSEL Power Supply, Noise Filter 2025 Product Catalog
PDAAC-DC Power Supplies Enclosed TypePDA50FOrdering informationPD A 50 F -O -O1 2 3 4 5 6RExample recommended EMI/EMC filterNAC-06-472High voltage pulse noise type : NAP seriesLow leakage current type : NAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *1C: with CoatingN : with coverFor option details, refer toInstruction Manual 8.1.*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.MODELPDA50F-5PDA50F-12PDA50F-24MAX OUTPUT WATTAGE[W]*25051.652.8DC OUTPUT*25V 10A12V 4.3A24V 2.2ASPECIFICATIONSMODELPDA50F-5PDA50F-12PDA50F-24VOLTAGE[VAC]*285 - 264 1f(Refer to Instruction Manual 1.1)CURRENT[A]FREQUENCY[Hz]50 / 60 (45 - 440)INPUTACIN 100V 81.5typ 82.5typ 85.0typEFFICIENCY[%]ACIN 230V 85.0typ 85.0typ 87.5typACIN 100V 15typ (Io=100%) at cold startINRUSH CURRENT[A]ACIN 230V 35typ (Io=100%) at cold startLEAKAGE CURRENT[mA]0.3 / 0.65 max (ACIN 100V / 240V, 60Hz, Io=100%, According to IEC62368-1, and DEN-AN)VOLTAGE[V]51224CURRENT[A]*2104.32.2LINE REGULATION[mV]*320max48max96maxLOAD REGULATION[mV]*340max100max150maxRIPPLE[mVp-p]OUTPUT0 to +50C 120max 150max 150maxRIPPLE NOISE[mVp-p]-20 to 0C 160max 180max 180max*4Io=0 to 15%360max360max360maxTEMPERATURE REGULATION[mV]0 to +50C 50max 120max 240max-20 to +50C 60max 150max 290maxDRIFT[mV]*520max48max96maxSTART-UP TIME[ms]80typ (ACIN 100V, Io=100%)HOLD-UP TIME[ms]20typ (ACIN 100V, Io=100%) / 140typ (ACIN 230V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]4.00 to 5.5010.0 to 13.219.2 to 27.0OUTPUT VOLTAGE SETTING[V]5.00 to 5.1512.00 to 12.4824.00 to 24.96PROTECTION OVERCURRENT PROTECTIONWorks over 105% of rating and recovers automaticallyCIRCUIT AND OVERVOLTAGE PROTECTION5.75 to 7.0015.0 to 18.030.0 to 37.0OTHERSREMOTE SENSINGNot providedINPUT-OUTPUT3,000VAC 1minute, Cutoff current = 10mA, 500VDC 100MW min (At Room Temperature)ISOLATIONINPUT-FG2,000VAC 1minute, Cutoff current = 10mA, 500VDC 100MW min (At Room Temperature)OUTPUT-FG500VAC 1minute, Cutoff current = 25mA, 500VDC 100MW min (At Room Temperature)OPERATING TEMP.,HUMID.AND ALTITUDE *2-20 to +70C, 20 - 90%RH (Non condensing), 5,000m (16,500feet) maxENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axisSAFETY ANDAGENCY APPROVALSUL62368-1, C-UL (equivalent to CAN/CSA-C22.2No.62368-1), EN62368-1, Complies with DEN-ANNOISECONDUCTED NOISEComplies with CISPR11-B, CISPR32-B, EN55011-B, EN55032-B, FCC Part15-B, FCC Part18-B, VCCI-BREGULATIONSHARMONIC ATTENUATOR *6Complies with IEC61000-3-2 (Class A) (No built-in power factor correction)OTHERS*1 The listed options may affect the published standard specifications. Please contact us fordetailed product specifications.*2 Derating is required.Please contact us for DC input.*3 At low load conditions, the burst mode operation will start. To check load regulation, you willneed to measure the characteristics at average mode with instruments.*4 This is the value that measured on measuring board with capacitor of 22mF at 150mm fromoutput terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter(Equivalent to KEISOKU-GIKEN:RM104).Ripple and ripple noise spec is change at Io=0 to 15% by burst operation.*5 Drift is the change in DC output for an eight hour period after a half-hour warm-up at25C, with the input voltage held constant at the rated input/output.*6 Please contact us about another class. When two or more units are operating it maynot comply with the IEC61000-3-2. Please contact us for details.* To meet the specification, do not operate overload condition.* Parallel operation is not possible.* Sound noise may be generated by power supply in case of pulse load.PDA-6? 34 ?