Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
MG15,MG30,MG40,MG80-seriesDeratingDerating curve for input voltage?MGF O 4005 O100? MGFO4024O, MGFO4048O, MGFO8024O and MGFO8048O100Load factor [%]Load factor [%]8070004.59Input Voltage [V]1300912183618243676Input Voltage [V]Ambient temperature derating curve!It is necessary to note thermal fatigue life by power cycle. Please reduce the temperature fl uctuation range as much as possible when theup and down of temperature are frequently generated.!In case of forced air, ventilation must keep the temperature of point below the temperatures shown in Instruction Manual 7.?MG15/MGF15 (Rated Input Voltage)(1) In the case of Convection Cooling(2) In the case of Forced Air Cooling (1.0m/s)(Excluding MGW15O05/MGFW15O05)100100Load factor [%]50Natural Convection1 MGW15O05 / MGFW15O052 others1 2Load factor [%]50Forced air (1.0m/s)MG0-40 -20 0 20 40 (55) 60 80 (85) 100Ambient temperature Ta [C](3) In the case of Forced Air Cooling (1.0m/s, 2.5m/s)(MGW15O05/MGFW15O05)0-40 -20 0 20 40 60 80(85)100Ambient temperature Ta[C]100Load factor [%]50Forced air1 1.0m/s2 2.5m/s1 20-40 -20 0 20 40 60 80(85)100Ambient temperature Ta [C]?MG30/MGF30 (Rated Input Voltage)(1) In the case of Convection Cooling100(2) In the case of Forced Air Cooling (1.0m/s)(Excluding MGW30O05 and MGFW30O12/15)100Load factor [%]501 32Natural Convection1 MGFS302412MGFW302415 / 48152 MGFS302415 / 4812 / 48153 othersLoad factor [%]50Forced air (1.0m/s)0-40 -20 0 20 40 (55) 60 80 (85) 100Ambient temperature Ta [C](3) In the case of Forced Air Cooling (1.0m/s, 1.5m/s)(MGW30O05 and MGFW30O12/15)0-40 -20 0 20 40 60 80(85)100Ambient temperature Ta[C]100Load factor [%]50Forced air1 1.0m/s2 1.5m/s1 20-40 -20 0 20 40 60 80(85)100Ambient temperature Ta [C]? 389 ?MG-78