title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
396/916

This page is the summary of page 396 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

RDC-DC Converters PCB Mount TypeSUW1R5Ordering informationSU W 1R5 12 12 B P1 2 3 4 5 6 71 Series name2 Dual output3 Output wattage4 Input voltage5 Output voltage6 Mounting typeB : SMDC : DIP7Packing formBlank: Plastic coverP : Tray (SMD type)SU . SUC/SUTMODELSUW1R50512SUW1R50515SUW1R51212SUW1R51215SUW1R52412SUW1R52415SUW1R54812SUW1R54815MAX OUTPUT WATTAGE[W]1.561.51.561.51.561.51.561.5DC OUTPUTVOLTAGE[V] * 1t12 or +24 t15 or +30 t12 or +24 t15 or +30 t12 or +24 t15 or +30 t12 or +24 t15 or +30CURRENT[A] 0.065 0.05 0.065 0.05 0.065 0.05 0.065 0.05SPECIFICATIONSINPUTOUTPUTMODELSUW1R50512SUW1R50515SUW1R51212SUW1R51215SUW1R52412SUW1R52415SUW1R54812SUW1R54815VOLTAGE[V]DC4.5 -9DC9 -18DC18 -36DC36 -76CURRENT[A]*2 0.433typ0.417typ0.173typ0.167typ0.087typ0.083typ0.043typ0.042typEFFICIENCY[%]*2 72typ72typ75typ75typ75typ75typ75typ75typVOLTAGE[V]t12(+24)t15(+30)t12(+24)t15(+30)t12(+24)t15(+30)t12(+24)t15(+30)CURRENT[A]0.0650.050.0650.050.0650.050.0650.05LINE REGULATION[mV]60max75max60max75max60max75max60max75maxLOAD REGULATION[mV]600max750max600max750max600max750max600max750maxRIPPLE[mVp-p]RIPPLE NOISE[mVp-p] -20 to+55C *3 150max 150max 150max 150max 150max 150max 150max 150max-40 to -20C *3 200max 200max 200max 200max 200max 200max 200max 200maxTEMPERATURE REGULATION[mV]DRIFT[mV]*4 50max60max50max60max50max60max50max60maxSTART-UP TIME[ms]20max (Minimum input, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGEFixed (TRM pin open) t5% adjustable by external VROUTPUT VOLTAGE SETTING[V] (t5%)11.40 -12.6014.25 -15.7511.40 -12.6014.25 -15.7511.40 -12.6014.25 -15.7511.40 -12.6014.25 -15.75PROTECTIONCIRCUIT ANDOTHERSOVERCURRENT PROTECTIONWorks over 105% ofrating and recovers automaticallyISOLATION INPUT-OUTPUTENVIRONMENTSAFETYOTHERSOPERATING TEMP.,HUMID.AND ALTITUDESTORAGE TEMP.,HUMID.AND ALTITUDEVIBRATIONIMPACTAGENCY APPROVALSCASE SIZE/WEIGHTCOOLING METHODAC500V 1minute, Cutoff current =10mA, DC500V 50MW min (20t15C)-40 to +85C, 20 -95%RH (Non condensing) (Refer to“Derating”), 3,000m (10,000feet) max-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max10 -55Hz, 98.0m/s 2 (10G), 3minutes period, 60minutes each along X, Yand Z axis490.3m/s 2 (50G), 11ms, once each along X, Yand Z axisUL60950-1, C-UL, EN62368-121.4X6.5X12.2mm [0.84X0.26X0.48 inches] (WXHXD) /2g maxConvection/Forced air*1 Output pins can be connected in series to make a 24V/30V output.*2 Rated input 5V, 12V, 24V or 48V DC Io=100%*3 Ripple and Ripple Noise is measured by using measuring board with capacitor with in 25mm from output pin terminals.*4 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.* Parallel operation with other model is not possible.SU . SUC/SUT-4 ? 394 ?