Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
RDC-DC Converters PCB Mount TypeSUW10Ordering informationSU W 10 12 12 B P -O1 2 3 4 5 6 7 81 Series name2 Dual output3 Output wattage4 Input voltage5 Output voltage6 Mounting typeB : SMDC : DIP7Packing formBlank: Plastic coverP : Tray(SMD type)8 OptionalG : Capacitor betweenInput and Output isremoved.SU . SUC/SUTMODELSUW100512SUW100515SUW101212SUW101215SUW102412SUW102415SUW104812SUW104815MAX OUTPUT WATTAGE[W]10.810.510.810.510.810.510.810.5DC OUTPUTVOLTAGE[V] * 1t12 or +24 t15 or +30 t12 or +24 t15 or +30 t12 or +24 t15 or +30 t12 or +24 t15 or +30CURRENT[A] 0.45 0.35 0.45 0.35 0.45 0.35 0.45 0.35SPECIFICATIONSMODELSUW100512SUW100515SUW101212SUW101215SUW102412SUW102415SUW104812SUW104815VOLTAGE[V]DC4.5 -9DC9 -18DC18 -36DC36 -76INPUTCURRENT[A]*2 2.51typ2.44typ1.05typ1.02typ0.523typ0.509typ0.262typ0.254typEFFICIENCY[%]*2 86typ86typ86typ86typ86typ86typ86typ86typVOLTAGE[V]t12(+24)t15(+30)t12(+24)t15(+30)t12(+24)t15(+30)t12(+24)t15(+30)CURRENT[A]0.450.350.450.350.450.350.450.35LINE REGULATION[mV]60max75max60max75max60max75max60max75maxLOAD REGULATION[mV]600max750max600max750max600max750max600max750maxRIPPLE[mVp-p]OUTPUTRIPPLE NOISE[mVp-p] -20 to+55C *3 150max 150max 150max 150max 150max 150max 150max 150max-40 to -20C *3 200max 200max 200max 200max 200max 200max 200max 200maxTEMPERATURE REGULATION[mV]DRIFT[mV]*4 50max60max50max60max50max60max50max60maxSTART-UP TIME[ms]OUTPUT VOLTAGE ADJUSTMENT RANGE20max (Minimum input, Io=100%)Fixed (TRM pin open) t5% adjustable by external VROUTPUT VOLTAGE SETTING[V] (t5%)11.40 -12.6014.25 -15.7511.40 -12.6014.25 -15.7511.40 -12.6014.25 -15.7511.40 -12.6014.25 -15.75PROTECTION OVERCURRENT PROTECTION Works over 105% ofrating and recovers automaticallyCIRCUIT ANDOTHERS REMOTE ON/OFF Provided (Negative logic L:ON, H:OFF)ISOLATIONINPUT-OUTPUTAC500V 1minute, Cutoff current =10mA, DC500V 50MW min (20t15C)ENVIRONMENTSAFETYOTHERSOPERATING TEMP.,HUMID.AND ALTITUDESTORAGE TEMP.,HUMID.AND ALTITUDEVIBRATIONIMPACTAGENCY APPROVALSCASE SIZE/WEIGHTCOOLING METHOD-40 to +85C, 20 -95%RH (Non condensing) (Refer to“Derating”), 3,000m (10,000feet) max-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max10 -55Hz, 98.0m/s 2 (10G), 3minutes period, 60minutes each along X, Yand Z axis490.3m/s 2 (50G), 11ms, once each along X, Yand Z axisUL60950-1, C-UL, EN62368-139.2X6.5X21.0mm [1.54X0.26X0.83 inches] (WXHXD) /6g maxConvection/Forced air*1 Output pins can be connected in series to make a 24V/30V output.*2 Rated input 5V, 12V, 24V or 48V DC Io=100%*3 Ripple and Ripple Noise is measured by using measuring board with capacitor with in 25mm from output pin terminals.*4 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.* Parallel operation with other model is not possible.SU . SUC/SUT-16 ? 406 ?