Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
RDC-DC Converters PCB Mount TypeSUCW1R5Ordering informationSUC W 1R5 12 12 B P -O1 2 3 4 5 6 7 81 Series name2 Dual output3 Output wattage4 Input voltage5 Output voltage6 Mounting typeB : SMDC : DIP7Packing formBlank: Plastic coverP : Tray (SMD type)8OptionalC : with coating (only DIPtype)** Safety standards arependingSU . SUC/SUTMODELSUCW1R50512SUCW1R50515SUCW1R51212SUCW1R51215SUCW1R52412SUCW1R52415SUCW1R54812SUCW1R54815MAX OUTPUT WATTAGE[W]1.561.51.561.51.561.51.561.5DC OUTPUTVOLTAGE[V] * 1t12 or +24 t15 or +30 t12 or +24 t15 or +30 t12 or +24 t15 or +30 t12 or +24 t15 or +30CURRENT[A] 0.065 0.05 0.065 0.05 0.065 0.05 0.065 0.05SPECIFICATIONSINPUTOUTPUTMODELSUCW1R50512SUCW1R50515SUCW1R51212SUCW1R51215SUCW1R52412SUCW1R52415SUCW1R54812SUCW1R54815VOLTAGE[V]DC4.5 -9DC9 -18DC18 -36DC36 -76CURRENT[A]*2 0.446typ0.429typ0.178typ0.171typ0.089typ0.086typ0.045typ0.043typEFFICIENCY[%]*2 70typ70typ73typ73typ73typ73typ73typ73typVOLTAGE[V]t12(+24)t15(+30)t12(+24)t15(+30)t12(+24)t15(+30)t12(+24)t15(+30)CURRENT[A]0.0650.050.0650.050.0650.050.0650.05LINE REGULATION[mV]60max75max60max75max60max75max60max75maxLOAD REGULATION[mV]600max750max600max750max600max750max600max750maxRIPPLE[mVp-p]RIPPLE NOISE[mVp-p] -20 to+55C *3 150max 150max 150max 150max 150max 150max 150max 150max-40 to -20C *3 200max 200max 200max 200max 200max 200max 200max 200maxTEMPERATURE REGULATION[mV]DRIFT[mV]*4 50max60max50max60max50max60max50max60maxSTART-UP TIME[ms]20max (Minimum input, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGEFixed (TRM pin open) t5% adjustable by external VROUTPUT VOLTAGE SETTING[V] (t5%)11.40 -12.6014.25 -15.7511.40 -12.6014.25 -15.7511.40 -12.6014.25 -15.7511.40 -12.6014.25 -15.75PROTECTIONCIRCUIT ANDOTHERSOVERCURRENT PROTECTIONWorks over 105% ofrating and recovers automaticallyINPUT-OUTPUTISOLATION INPUT-CASEOUTPUT-CASEENVIRONMENTSAFETYOTHERSOPERATING TEMP.,HUMID.AND ALTITUDESTORAGE TEMP.,HUMID.AND ALTITUDEVIBRATIONIMPACTAGENCY APPROVALSCASE SIZE/WEIGHTCOOLING METHODAC500V 1minute, Cutoff current =10mA, DC500V 50MW min (20t15C)AC500V 1minute, Cutoff current =10mA, DC500V 50MW min (20t15C)AC500V 1minute, Cutoff current =10mA, DC500V 50MW min (20t15C)-40 to +85C, 20 -95%RH (Non condensing) (Refer to“Derating”), 3,000m (10,000feet) max-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max10 -55Hz, 98.0m/s 2 (10G), 3minutes period, 60minutes each along X, Yand Z axis490.3m/s 2 (50G), 11ms, once each along X, Yand Z axisUL60950-1, C-UL, EN62368-122.4X7.0X13.2mm [0.88X0.28X0.52 inches] (WXHXD) /3g maxConvection/Forced air*1 Output pins can be connected in series to make a 24V/30V output.*2 Rated input 5V, 12V, 24V or 48V DC Io=100%*3 Ripple and Ripple Noise is measured by using measuring board with capacitor with in 25mm from output pin terminals.*4 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.* Parallel operation with other model is not possible.SU . SUC/SUT-20 ? 410 ?