COSEL Power Supply, Noise Filter 2025 Product Catalog
PDAAC-DC Power Supplies Enclosed TypePDA300FOrdering informationPD A 300 F -O1 2 3 4 5RExample recommended EMI/EMC filterNAC-06-4721Series name2Single output3Output wattage4Universal input5 Output voltageHigh voltage pulse noise type : NAP seriesLow leakage current type : NAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.MODELPDA300F-12PDA300F-15PDA300F-24PDA300F-36PDA300F-48MAX OUTPUT WATTAGE[W]*1324330336324336ACIN 100V 12V 27A 15V 22A 24V 14A 36V 9A 48V 7ADC OUTPUT *1ACIN 230V *2 12V 27A 15V 22A 24V 14 (16.5) A 36V 9A 48V 7ASPECIFICATIONSMODELPDA300F-12PDA300F-15PDA300F-24PDA300F-36PDA300F-48VOLTAGE[VAC]*185 - 264 1f (Refer to Instruction Manual 1.1)CURRENT[A]FREQUENCY[Hz]50 / 60 (45-66)ACIN 100V 79.0typ 80.5typ 82.0typ 81.0typ 82.5typEFFICIENCY[%]INPUTACIN 230V 82.0typ 84.0typ 84.5typ 84.5typ 86.0typPOWER FACTORACIN 100V0.99typ(Io=100%)ACIN 230V0.95typACIN 100V 20typ (Io=100%) at cold startINRUSH CURRENT[A]ACIN 230V 40typ (Io=100%) at cold startLEAKAGE CURRENT[mA]0.4 / 0.75 max (ACIN 100V / 240V, 60Hz, Io=100%, According to IEC62368-1, and DEN-AN)VOLTAGE[V]1215243648ACIN 100V 27 22 14 9 7CURRENT[A] *2ACIN 230V 27 22 14 (16.5) 9 7LINE REGULATION[mV]48max60max96max144max192maxLOAD REGULATION[mV]100max120max150max150max300maxRIPPLE[mVp-p]*3OUTPUTTEMPERATURE0 to +50C120max150max240max360max480maxREGULATION[mV]-20 to +50C180max180max290max440max600maxDRIFT[mV]*448max60max96max144max192maxSTART-UP TIME[ms]300typ (ACIN 100V, Io=100%)HOLD-UP TIME[ms]35typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]8.25 to 13.2010.50 to 16.5016.50 to 26.4025.20 to 39.6038.40 to 56.00OUTPUT VOLTAGE SETTING[V]12.00 to 12.4815.00 to 15.6024.00 to 24.9636.00 to 37.4448.00 to 49.92OVERCURRENT PROTECTION Works over 105% of rating and recovers automaticallyPROTECTIONOVERVOLTAGE PROTECTION[V] 14.4 to 18.6 18.0 to 23.3 28.8 to 37.2 43.2 to 54.0 57.6 to 80.0CIRCUIT ANDOTHERSREMOTE SENSINGProvidedREMOTE ON/OFFProvidedINPUT-OUTPUT-RC3,000VAC 1minute, Cutoff current = 10mA, 500VDC 100MWmin (At Room Temperature)ISOLATIONOUTPUT-RC-AUX500VAC 1minute, Cutoff current = 100mA, 500VDC 100MW min (At Room Temperature)OPERATING TEMP.,HUMID.AND ALTITUDE *1-20 to +70C (Refer to“Derating”), 20 - 90%RH (Non condensing)ENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axisSAFETY ANDAGENCY APPROVALS (At only AC input) UL62368-1, C-UL (equivalent to CAN/CSA-C22.2No.62368-1), EN62368-1, Complies with DEN-ANNOISECONDUCTED NOISEComplies with CISPR11-B, CISPR32-B, EN55011-B, EN55032-B, FCC Part15-B, FCC Part18-B, VCCI-BREGULATIONSHARMONIC ATTENUATOR*5Complies with IEC61000-3-2 (Class A)OTHERS*1 Derating is required. Please contact us for DC input.*2 ( ) means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manualin detail.*3 This is the value measured on measuring board with capacitor of 22μF within 150mm fromoutput terminal.Measured by 20MHz Oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN :RM-104).*4 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25a, withthe input voltage held constant at the rated input/output.PDA-12? 40 ?*5 Please contact us about another class. When two or more units are operating it may notcomply with the IEC61000-3-2. Please contact us for details.* To meet the specification, do not operate overload condition.* Sound noise may be generated by power supply in case of pulse load.