title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
44/916

This page is the summary of page 44 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

PDAAC-DC Power Supplies Enclosed TypePDA600FOrdering informationPD A 600 F -O1 2 3 4 5RExample recommended EMI/EMC filterNAC-10-4721Series name2Single output3Output wattage4Universal input5 Output voltageHigh voltage pulse noise type : NAP seriesLow leakage current type : NAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.MODELPDA600F-12PDA600F-15PDA600F-24PDA600F-36PDA600F-48MAX OUTPUT WATTAGE[W]*1636645648648624ACIN 100V 12V 53A 15V 43A 24V 27A 36V 18A 48V 13ADC OUTPUT *1ACIN 230V *2 12V 53A 15V 43A 24V 27(31)A 36V 18A 48V 13ASPECIFICATIONSMODELPDA600F-12PDA600F-15PDA600F-24PDA600F-36PDA600F-48VOLTAGE[VAC]*185 - 264 1f (Refer to Instruction Manual 1.1)CURRENT[A]FREQUENCY[Hz]50 / 60 (45-66)ACIN 100V 83.0typ 83.5typ 85.5typ 84.5typ 86.0typEFFICIENCY[%]INPUTACIN 230V 85.5typ 86.5typ 88.0typ 87.0typ 89.0typPOWER FACTORACIN 100V0.98typ(Io=100%)ACIN 230V0.95typACIN 100V 20/40typ (Io=100%) (Primary / Secondary inrush current) (More than 3 sec. to re-start)INRUSH CURRENT[A]ACIN 230V 40/40typ (Io=100%) (Primary / Secondary inrush current) (More than 3 sec. to re-start)LEAKAGE CURRENT[mA]0.4 / 0.75 max (ACIN 100V / 240V, 60Hz, Io=100%, According to IEC62368-1, and DEN-AN)VOLTAGE[V]1215243648ACIN 100V 53 43 27 18 13CURRENT[A] *2ACIN 230V 53 43 27 (31)18 13LINE REGULATION[mV]48max60max96max144max192maxLOAD REGULATION[mV]100max120max150max150max300maxRIPPLE[mVp-p]*3OUTPUTTEMPERATURE0 to +50C120max150max240max360max480maxREGULATION[mV]-20 to +50C180max180max290max440max600maxDRIFT[mV]*448max60max96max144max192maxSTART-UP TIME[ms]400typ (ACIN 100V, Io=100%)HOLD-UP TIME[ms]35typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]8.25 to 13.2010.50 to 16.5016.50 to 26.4025.20 to 39.6038.40 to 56.00OUTPUT VOLTAGE SETTING[V]12.00 to 12.4815.00 to 15.6024.00 to 24.9636.00 to 37.4448.00 to 49.92OVERCURRENT PROTECTION Works over 105% of rating and recovers automaticallyPROTECTIONOVERVOLTAGE PROTECTION[V] 14.4 to 18.6 18.0 to 23.3 28.8 to 37.2 43.2 to 54.0 57.6 to 80.0CIRCUIT ANDOTHERSREMOTE SENSINGProvidedREMOTE ON/OFFProvidedINPUT-OUTPUT-RC3,000VAC 1minute, Cutoff current = 10mA, 500VDC 100MWmin (At Room Temperature)ISOLATIONOUTPUT-RC-AUX500VAC 1minute, Cutoff current = 100mA, 500VDC 100MW min (At Room Temperature)OPERATING TEMP.,HUMID.AND ALTITUDE *1-20 to +70C (Refer to“Derating”), 20 - 90%RH (Non condensing)ENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axisSAFETY ANDAGENCY APPROVALS (At only AC input) UL62368-1, C-UL (equivalent to CAN/CSA-C22.2No.62368-1), EN62368-1, Complies with DEN-ANNOISECONDUCTED NOISEComplies with CISPR11-B, CISPR32-B, EN55011-B, EN55032-B, FCC Part15-B, FCC Part18-B, VCCI-BREGULATIONSHARMONIC ATTENUATOR*5Complies with IEC61000-3-2 (Class A)OTHERS*1 Derating is required. Please contact us for DC input.*2 ( ) means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manualin detail.*3 This is the value measured on measuring board with capacitor of 22μF within 150mm fromoutput terminal.Measured by 20MHz Oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN :RM-104).*4 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25a, withthe input voltage held constant at the rated input/output.PDA-14? 42 ?*5 Please contact us about another class. When two or more units are operating it may notcomply with the IEC61000-3-2. Please contact us for details.* To meet the specification, do not operate overload condition.* Sound noise may be generated by power supply in case of pulse load.