Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
AC-DC Power Supplies Enclosed TypeInstruction ManualLife expectancy of fan [H]100,000Io=30%(Vin=85?264VAC)Io=50%(Vin=85?264VAC)Io=70%(Vin=85?264VAC)Io=100%(Vin=85?264VAC)10,00030 40 50 60 70 80Ambient temperature [C](a) PCA1500F-5,-12,-155 Others5.1 Output Current Monitor!The output current can be monitored by voltage between the terminalCB and COM.!Fig.5.1 shows the relationship between the voltage of the terminalCB and the output current.The output current shown in Fig.5.1 is for reference only.[V]3Life expectancy of fan [H]100,000Io=30%(Vin=85?264VAC)Io=50%(Vin=85?264VAC)Io=70%(Vin=85?264VAC)Io=100%(Vin=85?170VAC)Io=100%(Vin=170?264VAC)Voltage ofCB terminal0100 [%]Load factorOutput currentLoad factor :Rated current10,00030 40 50 60 70 80Ambient temperature [C](b) PCA1500F-24,-32,-48Fig.4.4 Life expectancy of fan (PCA1500F)!Warranty termThe warranty period is 5 years if a power supply is used within“Derating”.Warranty does not apply if used outside of“Derating”.Fig.5.1 Load current conversion graph!Please note the following notes when measuring the voltage ofthe terminal CB.-Wire carefully to avoid malfunction caused by noise.-Use a measuring instrument whose input impedance is 500kWor more.-Do not short-circuit between CB terminal and COM terminal tonot cause a failure.-Do not connect more than 1μF to CB terminal to prevent outputvoltage malfunction.PCA-29