title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
448/916

This page is the summary of page 448 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

DC-DC Converters PCB Mount Value-added TypeSTMGFW15Ordering informationSTMGF W 15 24 05 -O1 2 3 4 5 6DIN rail installation type(Option : -N2)1 Series name2 Dual output3 Output wattage4 Input voltage5 Output voltage6 OptionalG : Capacitor betweenInput and Output is removed.R : with Remote ON/OFF(Positive logic control)J : Input/Output ConnectorJN1 : Connector with case coverN2 : With DIN rail installation typeJN3 : Connector with cover(plastic)and DIN rail installation type*When the option is setspecifications may vary.Standard typeConnector type(Option : -J)Connector with case cover(Option : -JN1)STMG*Please remove short piece on CN4 to enable remote ON/OFF function.MODELSTMGFW152405 STMGFW152412 STMGFW152415 STMGFW154805 STMGFW154812 STMGFW154815MAX OUTPUT WATTAGE[W] 15 15.6 15 15 15.6 15VOLTAGE[V] *1±5 or +10±12 or +24±15 or +30±5 or +10±12 or +24±15 or +30DC OUTPUTCURRENT[A] 1.5 0.65 0.5 1.5 0.65 0.5SPECIFICATIONSMODELSTMGFW152405 STMGFW152412 STMGFW152415 STMGFW154805 STMGFW154812 STMGFW154815VOLTAGE[V]DC9 - 36DC18 - 76INPUTCURRENT[A]*20.74typ0.74typ0.70typ0.37typ0.37typ0.36typEFFICIENCY[%]*284typ88typ89typ84typ87typ88typVOLTAGE[V]±5(+10)±12(+24)±15(+30)±5(+10)±12(+24)±15(+30)CURRENT[A]1.50.650.51.50.650.5LINE REGULATION[mV]40max60max75max40max60max75maxLOAD REGULATION[mV]RIPPLE[mVp-p]0 to +60C100max100max100max100max100max100maxOUTPUT*6 -20 to +60C200max200max200max200max200max200maxTEMPERATURE REGULATION[mV]DRIFT[mV]*750max50max60max50max50max60maxSTART-UP TIME[ms]30max (Minimum input, Io=100%)OUTPUT VOLTAGE SETTING[V]*84.93 - 5.2411.76 - 12.5014.60 - 15.514.93 - 5.2411.76 - 12.5014.60 - 15.51PROTECTION OVERCURRENT PROTECTIONCIRCUIT ANDWorks over 105% of rating and recovers automaticallyOTHERSREMOTE ON/OFFProvided (Negative logic L:ON, H:OFF)ISOLATIONENVIRONMENTSTMG-6INPUT-RC-OUTPUTINPUT-RC-FGOUTPUT-FGOPERATING TEMP.,HUMID.AND ALTITUDESTORAGE TEMP.,HUMID.AND ALTITUDEVIBRATIONIMPACTDC1,500V 1minute, Cutoff current = 10mA, DC500V 1,000MW min (20±15C)DC1,000V 1minute, Cutoff current = 10mA, DC500V 1,000MW min (20±15C)DC1,000V 1minute, Cutoff current = 10mA, DC500V 1,000MW min (20±15C)-20 to +70C, 20 to 95%RH (Non condensing) (Refer to“Derating”), 3,000m (10,000feet) max-20 to +75C, 20 to 95%RH (Non condensing), 9,000m (30,000feet) max10 - 55Hz, 19.6m/s 2 (2G), 3minutes period, 60minutes each along X, Y and Z axis196.1m/s 2 (20G), 11ms, once each along X, Y and Z axisSAFETY AGENCY APPROVALS UL60950-1, C-UL, EN62368-1 CompliesOTHERSCASE SIZE/WEIGHTCOOLING METHOD52X27X93mm [2.05X1.06X3.66 inches] (WXHXD) / 110g max (When the option is set, refer to the page STMG-7)Convection/Forced air*1Single output +10V, +24V, +30V with no use of COM.*2Rated input 12V, 24V or 48V DC lo=100%*3Symmetrical loading from 5% to 100%.*4Symmetrical loading from 20% to 100%.*5Refer to the instruction manual 7.*6Measured by 100MHz oscilloscpe or Ripple-Noise meter (Equivalent to KIKUSUI-GIKEN :RM103).*7Drift is the DC output accuracy for eight hours period after a half-hour warm-up at 25C.? 446 ?*8 Rated input voltage (DC24V, DC48V), rated output wattage, ambient temperature at 25C.* Parailel operation with other model is not possible.