Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
DC-DC Converters PCB Mount Value-added TypeSTMGFW30Ordering informationSTMGF W 30 24 05 -O1 2 3 4 5 6DIN rail installation type(Option : -N2)1 Series name2 Dual output3 Output wattage4 Input voltage5 Output voltage6 OptionalG : Capacitor betweenInput and Output is removed.R : with Remote ON/OFF(Positive logic control)J : Input/Output ConnectorN1 : With case coverN2 : With DIN rail installation typeN3 : With cover(plastic)and DIN rail installation type*When the option is setspecifications may vary.Standard typeConnector type(Option : -J)With case cover(Option : -N1)STMG*Please remove short piece on CN4 to enable remote ON/OFF function.MODELSTMGFW302405 STMGFW302412 STMGFW302415 STMGFW304805 STMGFW304812 STMGFW304815MAX OUTPUT WATTAGE[W] 20 30 30 20 30 30VOLTAGE[V] *1±5 or +10±12 or +24±15 or +30±5 or +10±12 or +24±15 or +30DC OUTPUTCURRENT[A] 2 1.25 1 2 1.25 1SPECIFICATIONSMODELSTMGFW302405 STMGFW302412 STMGFW302415 STMGFW304805 STMGFW304812 STMGFW304815VOLTAGE[V]DC9 - 36DC18 - 76INPUTCURRENT[A]*20.98typ1.42typ1.44typ0.49typ0.71typ0.72typEFFICIENCY[%]*285typ88typ87typ85typ88typ87typVOLTAGE[V]±5(+10)±12(+24)±15(+30)±5(+10)±12(+24)±15(+30)CURRENT[A]21.25121.251LINE REGULATION[mV]40max60max75max40max60max75maxLOAD REGULATION[mV]RIPPLE[mVp-p]0 to +60C100max100max100max100max100max100maxOUTPUT*6 -20 to +60C200max200max200max200max200max200maxTEMPERATURE REGULATION[mV]DRIFT[mV]*750max50max60max50max50max60maxSTART-UP TIME[ms]30max (Minimum input, Io=100%)OUTPUT VOLTAGE SETTING[V]*84.93 - 5.2411.76 - 12.5014.60 - 15.514.93 - 5.2411.76 - 12.5014.60 - 15.51PROTECTION OVERCURRENT PROTECTIONWorks over 105% of rating and recovers automaticallyCIRCUIT AND OVERVOLTAGE PROTECTION[V]Works over 120 to 160% of rating (Total of +V and -V)OTHERSREMOTE ON/OFFProvided (Negative logic L:ON, H:OFF)INPUT-RC-OUTPUTDC1,500V 1minute, Cutoff current = 10mA, DC500V 1,000MW min (20±15C)ISOLATIONINPUT-RC-FGDC1,000V 1minute, Cutoff current = 10mA, DC500V 1,000MW min (20±15C)OUTPUT-FGDC1,000V 1minute, Cutoff current = 10mA, DC500V 1,000MW min (20±15C)OPERATING TEMP.,HUMID.AND ALTITUDE-20 to +70C, 20 to 95%RH (Non condensing) (Refer to“Derating”), 3,000m (10,000feet) maxENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each along X, Y and Z axisSAFETYAGENCY APPROVALSUL60950-1, C-UL, EN62368-1 CompliesOTHERS*1Single output +10V, +24V, +30V with no use of COM.*2Rated input 12V, 24V or 48V DC lo=100%*3Symmetrical loading from 5% to 100%.*4Symmetrical loading from 20% to 100%.*5Refer to the instruction manual 7.*6Measured by 100MHz oscilloscpe or Ripple-Noise meter (Equivalent to KIKUSUI-GIKEN :RM103).STMG-12? 452 ?*7Drift is the DC output accuracy for eight hours period after a half-hour warm-up at 25C.*8Rated input voltage (DC24V, DC48V), rated output wattage, ambient temperature at 25C.*Parailel operation with other model is not possible.