title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
470/916

This page is the summary of page 470 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

DC-DC Converters POL TypeBRFSOrdering informationBRF S 60 S -O1 2 3 4 5R1 Series name2 Single output3 Output current30:30A40:40A60:60A100:100A120:120A150:150A4 TypeBlank : Standard typeS : Small type (only 60A)5 OptionalR : Positive logic remoteon/offI : POWERGOOD(only BRFS30/40/60S)* Other models has POWERGOODfunction normally.P : Parallel operation(only BRFS40/60S)Y1 : Fast transient response(only BRFS100)BRFS/BRDSMODELBRFS30BRFS40BRFS60BRFS60SBRFS100BRFS120BRFS150MAX OUTPUT CURRENT[A]30.040.060.060.0100.0120.0150.0DC OUTPUT0.8 - 3.63V0.6 - 2.0V0.7 - 2.0V0.6 - 2.0V0.7 - 2.0V0.6 - 1.8V0.6 - 1.8V *7SPECIFICATIONSINPUTOUTPUTPROTECTIONCIRCUIT ANDOTHERSMODELBRFS30BRFS40BRFS60BRFS60SBRFS100BRFS120BRFS150VOLTAGE[V]DC4.5 - 14.0CURRENT[A]*13.41 typ4.52 typ6.82 typ6.71 typ11.24 typ13.50 typ16.90 typEFFICIENCY[%]*188.0 typ88.5 typ88.0 typ89.5 typ89.0 typ89.0 typ89.0 typVOLTAGE[V]*20.8 - 3.630.6 - 2.00.7 - 2.00.6 - 2.00.7 - 2.00.6 - 1.80.6 - 1.8 *7CURRENT[A]30406060100120150LINE REGULATION[mV]5LOAD REGULATION[mV]5RIPPLE[mVp-p]*325RIPPLE NOISE[mVp-p]*350OUTPUT VOLTAGE SETTING [%Vo]±1DRIFT[mV]*45START-UP TIME[ms]8.0 typ12.0 typ *68.0 typ12.0 typ *6OUTPUT VOLTAGEAdjustable by external resistor[V]ADJUSTMENT RANGE 0.8 - 3.63 0.6 - 2.0 0.7 - 2.0 0.6 - 2.0 0.7 - 2.0 0.6 - 1.8 0.6 - 1.8 *7OUTPUT VOLTAGE TOTAL REGULATION [%Vo]*5±3OVERCURRENT PROTECTIONWorks over 105% of rating (auto recovery type)REMOTE SENSING Available (+S only) Available Available (+S only) AvailableREMOTE ON/OFFISOLATION INPUT-OUTPUT non-isolatedENVIRONMENTOPERATING TEMP.,HUMID.AND ALTITUDESTORAGE TEMP.,HUMID.AND ALTITUDEVIBRATIONIMPACTAvailable Negative logic L:ON, H:OFF-40 to +85C, 20-95%RH (Non condensing) (Refer to“Derating”) 3,000m (10,000feet) max-40 to +100C, 20-95%RH (Non condensing), 9,000m (30,000feet) max10-55Hz, 49.0m/s 2 (5G), 3minutes period, 60minutes each along X, Y and Z axis196.1m/s 2 (20G), 11ms, once each along X, Y and Z axisSAFETY AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN62368-1OTHERSCASE SIZE/WEIGHTCOOLING METHOD33.0X9.5X13.5mm[1.3X0.37X0.53inches] (WXHXD) /10g maxConvection / Forced air33.0X10.9X13.5mm[1.3X0.43X0.53inches] (WXHXD) /12g max33.0X8.0X22.9mm[1.3X0.31X0.9inches] (WXHXD) /15g max33.0X12.7X13.5mm[1.3X0.5X0.53inches] (WXHXD) /12g max*1At rated input (DC12V) and rated output (1.2V) Ta=25C.*2Output voltage is adjusted to the minimum when TRM is opened.*3Ripple and ripple noise is measured by using measuring board with ceramic capacitor at 50mm from output pin.*4Drift is the change in DC output for an eight hour period after a half - hour warm - up at 25C, with the input voltage held.*5Output voltage setting is added line regulation and load regulation and temperature regulation used resistance of the 0.5% tolerance.*6The start-up time when using the RC terminal is same as other BRFS.*7The output voltage adjustment area determines by the input voltage.38.0X8.5X27.7mm[1.5X0.33X1.09inches] (WXHXD) /22g max33.0X12.7X22.9mm[1.3X0.5X0.9inches] (WXHXD) /14g max38.0X13.8X27.7mm[1.5X0.54X1.09inches] (WXHXD) /21g maxBRFS/BRDS-2? 468 ?