Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
AC-DC Power Supplies Enclosed TypeInstruction ManualNo.3 (Slave)Implement H-PA-16Implement H-SN-53? -W1!The PG signal dose not output unless any protection operates.!The logic for the PG signal is reversed.- +[Alarm function]!Table 6.5 shows the function of the built-in alarm.Table 6.5 alarm functionNo.2 (Slave)PGThe PG signal turns to“Low”when any protectionoperates.Open collector methodGood : HighBad : Low (0.5V max at 5mA)50V 5mA max- +PG0.1mF100kWNo.1 (Master)LoadFig.6.8 Internal circuit of alarmPGG- +Fig.6.7 Connection method in parallel (PCA300F, PCA600F)*Notes on parallel operation(1) Specifi cation value of ripple and ripple noise is tripled.(2) Load regulation is 3% of the rated output voltage.(3) Constant current set value external variable function cannot beused.(4) The remote sensing function can be used. Connect the sensingwire to the load only from the mastering power supply.*Usage notes for PG signal are shown below.(1) The PG signal turns to“High”when the output voltage is turnedoff with remote ON/OFF.(2) The PG signal turns to“High”when the output voltage is led tobe decreased by the adjustment or CC functions.(3) Circuit of the alarm (PG, PGG) is isolated from input, output, FG,AUX and terminals for various functions.? -E1 (PCA1000F)!This option is available for the following models.- PCA1000F-24, -32, -48!EMI classB!The difference from standard is shown Table 6.6.Table 6.6 -E1 option typeLEAKAGECURRENT [mA]CONDUCTEDNOISESAFETYAGENCYAPPROVALS1.0max (ACIN 240V 60Hz, Io=100%, Accordingto IEC60601-1)Complies with FCC Part15 classB, VCCI-B,CISPR32-B, EN55011-B, EN55032-BANSI/AAMI ES60601-1,EN60601-14 3 rdC-UL (equivalent to CAN/CSA-C22.2 No.60601-1)Not availablePCA-33