COSEL Power Supply, Noise Filter 2025 Product Catalog
DC-DC Converters PCB Mount TypeInstruction Manual7 TemperatureMeasuring Point!Please use the point A temperature (center of the case) shown inFigure 7.1, and the ambient temperature around the power supplyto be below the temperatures shown in Table 7.1.Point A (Center of the Case)Fig.7.1 Temperature Measuring Point on the case (Top View)Table 7.1 Point A and ambient temperatureModelMU1R5MU3MU6MU10Point A105C105C110C110Cambienttemperature100C100C95C90C8 Delivery Package Information!Please refer to Figure 8.1 for the packaging format (tray).The standard number of items in a package in purchasing is 30.The tray will be different when the order quantity is 30 or less.See Table 8.1 for the detail.Table 8.1 Tray Capacity (Units per Tray)ModelMU1R55max (P-MU1R5-2)30max (P-MU1R5-1)MU35max (P-MU1R5-2)30max (P-MU1R5-1)MU65max (P-MU6-2)30max (P-MU6-1)MU105max (P-MU6-2)30max (P-MU6-1)In case of fractions, the units are stored in numerical order.- The tray shall be transported and carried with keeping it horizontallyas less vibration.MUS . MUW-26