title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
498/916

This page is the summary of page 498 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

RDC-DC Converters Bus Converter . Power Module TypeCHS380Ordering informationCH S 380 48 12 -O1 2 3 4 5 61 Series name2 Single output3 Output power4 Input voltage48:DC36 - 76V5 Output voltage10:10V12:12V12H:12V(High efficiency type)6 OptionalR : with Remote ON/OFFPositive logic controlU : Shut down in protectioncircuit workingB : BasePlate option withMounting hole M3L2: Pin length 5.3mmL5: 5pins type (+S,-S,TRMless)CHSMODELCHS3804810CHS3804812CHS3804812HMAX OUTPUT WATTAGE[W]380.0384.0384.0DC OUTPUT10V 38A12V 32A12V 32ASPECIFICATIONSMODELCHS3804810CHS3804812CHS3804812HVOLTAGE[V]DC36 - 76INPUTCURRENT[A]*18.42typ8.47typ8.42typEFFICIENCY[%]*194.0typ94.5typ95.0typVOLTAGE[V]101212CURRENT[A]383232LINE REGULATION[mV]*620max24max24maxLOAD REGULATION[mV]*620max24max24maxRIPPLEOUTPUTRIPPLE NOISE[mVp-p]*2150max180max200maxTEMPERATURE REGULATION[mV]200max240max240maxDRIFT[mV]*330max40max40maxSTART-UP TIME[ms]50max (DCIN 48V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE*4Fixed (TRM pin open), adjustable by external resistor-10% / +10%OUTPUT VOLTAGE SETTING*1±1.6%OVERCURRENT PROTECTIONWorks over 105% of rating (Auto restart)PROTECTION OVERVOLTAGE PROTECTION 115% - 135% (Auto restart)CIRCUIT ANDOTHERSREMOTE SENSING ProvidedREMOTE ON/OFFProvided (Negative Logic L : ON, H :OFF)INPUT-OUTPUTDC2,250V or AC1,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)ISOLATIONINPUT-BASEPLATE*5DC2,250V or AC1,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)OUTPUT-BASEPLATE*5AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20±15C)OPERATING TEMP.,HUMID.AND ALTITUDE-40 to +85C, 20 - 95%RH (Non condensing) (Refer to“Derating”), 5,000m (16,000 feet) maxENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each along X, Y and Z axisSAFETYAGENCY APPROVALSUL60950-1, C-UL (CSA60950-1), EN62368-158.4X11.0X22.86mm [2.3X0.43X0.9 inches] (WXHXD) / 38g maxCASE SIZE/WEIGHTOTHERS58.9X12.7X23.26mm [2.32X0.5X0.92 inches] (WXHXD) / 50g max *5COOLING METHODConvection / Forced air / Conduction*1 At rated input (DC48V) and rated load. Ta=25C, 2m/s.*2 Ripple and ripple noise is measured by using measuring board with ceramic capacitor 22mF.*3 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.*4 Refer to the instruction manual for input voltage derating.*5BasePlate Option.*6 At input voltage DC36-76V(CHS3804810, CHS3804812), DC40-76V(CHS3804812H).CHS-16? 496 ?