Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
RPBA/PBWAC-DC Power Supplies Enclosed TypePBA10FOrdering informationPB A 10 F -O -O1 2 3 4 5 6Example recommended EMI/EMC filterNAC-06-472High voltage pulse noise type : NAP seriesLow leakage current type : NAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.Cover is optional*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *5C : with CoatingG : Low leakage currentE : Low leakage currentand EMI class AT : Vertical terminal blockJ1 : VH (J.S.T.) connector typeN : with Cover(UL508 is acquired)N1 : with DIN rail and CoverV : Output voltage settingpotentiometer externallyMODELPBA10F-5PBA10F-12PBA10F-24MAX OUTPUT WATTAGE[W]1010.812DC OUTPUT5V 2A12V 0.9A24V 0.5ASPECIFICATIONSMODELPBA10F-5PBA10F-12PBA10F-24VOLTAGE[V]AC85 -264 1f or DC110 -370 (AC50 or DC70 Please refer to the instruction manual 1.1 Input voltage *3)CURRENT[A]FREQUENCY[Hz]50/60 (47 -440) or DCINPUTACIN 100V 74typ 76typ 77typEFFICIENCY[%]ACIN 200V 74typ 76typ 77typACIN 100V 15typ (Io=100%)INRUSH CURRENT[A]ACIN 200V 30typ (Io=100%)LEAKAGE CURRENT[mA]0.15/0.30max (ACIN 100V/240V 60Hz, Io=100%, According to IEC62368-1, DENAN)VOLTAGE[V]51224CURRENT[A]20.90.5LINE REGULATION[mV]*6 20max48max96maxLOAD REGULATION[mV]*6 40max100max150maxRIPPLE[mVp-p]RIPPLE NOISE[mVp-p] 0to +50C *1 120max 150max 150maxOUTPUT-10 -0C *1 160max 180max 180maxTEMPERATURE REGULATION[mV]DRIFT[mV]*2 20max48max96maxSTART-UP TIME[ms]200typ(ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.HOLD-UP TIME[ms]20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]4.50 -5.5010.0 -13.219.2 - 27.0OUTPUT VOLTAGE SETTING[V]5.00 -5.1512.00 - 12.4824.00 -24.96OVERCURRENT PROTECTIONWorks over 105% ofrated current and recovers automaticallyPROTECTION OVERVOLTAGE PROTECTION[V] 5.75 -7.00 15.0 -18.0 30.0 - 37.0CIRCUIT ANDOTHERS OPERATING INDICATION LED (Green)REMOTE ON/OFFNoneINPUT-OUTPUTAC3,000V 1minute, Cutoff current =10mA, DC500V 50MWmin (At Room Temperature)ISOLATIONINPUT-FGAC2,000V 1minute, Cutoff current =10mA, DC500V 50MWmin (At Room Temperature)OUTPUT-FGAC500V 1minute, Cutoff current =25mA, DC500V 50MWmin (At Room Temperature)OPERATING TEMP.,HUMID.AND ALTITUDE-10 to +71C (Refer to“Derating”), 20 -90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 -90%RH (Non condensing) 9,000m (30,000feet) maxENVIRONMENTVIBRATION10 - 55Hz, 19.6m/s 2 (2G), 3minutes period, 60minutes each along X, Y and ZaxisIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axisSAFETY ANDAGENCY APPROVALS (At only ACinput) UL60950-1, C-UL(CSA60950-1), EN62368-1 Complies with DEN-ANNOISE CONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BREGULATIONSHARMONIC ATTENUATORComplies with IEC61000-3-2 (Not built-in to active filter *4) *7OTHERS*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN:RM101).*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 Derating is required.*4 When two or more units are used,they may not comply with the harmonic attenuator. Pleasecontact us for details.*5 Please contact us about safety approvals for the model with option.*6 Please contact us about dynamic load and input response.*7 Please contact us about class C.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.PBA/PBW-2? 50 ?