Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
RDC-DC Converters Bus Converter . Power Module TypeCQHS250Ordering informationCQH S 250 48 50 -O1 2 3 4 5 61 Series name2 Single output3 Output wattage4 Input voltage48:DC36 - 76V5 Output voltage6 OptionalR : with Remote ON/OFFPositive logic controlN : Auto restart in protectioncircuit workingB : Base plate option withMounting hole M3L2 :Pin length 5.3mmCQHSMODELCQHS2504832CQHS2504850MAX OUTPUT WATTAGE[W]252.8250DC OUTPUT32V 7.9A50V 5.0ASPECIFICATIONSMODELCQHS2504832CQHS2504850VOLTAGE[V]DC36 - 76CURRENT[A]*15.60typ5.54typINPUTEFFICIENCY[%]*194typ94typSTART-UP VOLTAGE[V]DC32 - 36HYSTERESIS VOLTAGE[V]DC2 minVOLTAGE[V]3250CURRENT[A]7.95.0LINE REGULATION[mV]64max100maxLOAD REGULATION[mV]64max100max-20 to +85C*2Vin=36-60V255max400maxRIPPLE[mVp-p] -20 to +85C*2Vin=60-76V320max500maxOUTPUT-40 to -20C *2320max500maxRIPPLE NOISE[mVp-p]TEMPERATURE REGULATION[mV]-40 to +85C640max1000maxDRIFT[mV]*3120max185maxSTART-UP TIME[ms]200max (DCIN 48V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V] *4Fixed (TRM pin open), adjustable by external resistor26.88 - 35.20 45.0 - 55.0OUTPUT VOLTAGE SETTING[V] *131.68 - 32.3249.50 - 50.50OVERCURRENT PROTECTIONWorks over 105% of rating, low voltage protection (shut down) function is built-in.PROTECTIONOVERVOLTAGE PROTECTION[V] 36.80 - 44.80 56.50 - 67.50CIRCUIT ANDOTHERS REMOTE SENSING ProvidedREMOTE ON/OFFProvided (Negative Logic L : ON, H :OFF)INPUT-OUTPUTDC1,500V or AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)ISOLATIONINPUT-BASE PLATE*5DC1,500V or AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)OUTPUT-BASE PLATE*5AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20±15C)OPERATING TEMP.,HUMID.AND ALTITUDE-40 to +85C, 20 - 95%RH (Non condensing) (Refer to“Derating”), 3,000m (10,000 feet) maxENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each along X, Y and Z axisSAFETYAGENCY APPROVALSUL60950-1, C-UL (CSA60950-1), EN62368-157.9X10.5X22.76mm [2.28X0.41X0.9 inches] (WXHXD) / 30g maxCASE SIZE/WEIGHTOTHERS58.4X12.7X23.26mm [2.3X0.5X0.92 inches] (WXHXD) / 45g max *5COOLING METHODConvection / Forced air / Conduction*1 At rated input(DC48V), rated load. Ta= 25C, 2m/s.*2 Ripple and ripple noise is measured by using measuring board. Refer to the manual.*3 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.*4 When the input voltage is in the range of DC36-40V, output voltage is limited. Refer to the manual.*5 Base Plate Option.? 520 ?CQHS-2