Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
RDC-DC Converters Bus Converter . Power Module TypeDCS1400BOrdering informationDC S 1400 B 28 -O1 2 3 4 5 61 Series name2 Single output3 Output wattage4 Input voltageB : 200 - 435VDC5 Output voltage6 OptionalT : with Mounting hole(f3.4 thru)R : with Remote ON/OFF(Positive logic control)N1: Auto restart from thermalprotectionP2: Built-in ORing MOSFETDCS* If remote on/off is not necessary, connect between RC & RCG.* Keep VTRM open, if output voltage adjustment is not necessary.* Keep ITRM open, if output current adjustment is not necessary.* If remote sensing is not necessary, connect between +Vout & +S and between -Vout & -S.MODELDCS1400B12DCS1400B24DCS1400B28DCS1400B36DCS1400B48DCS1400B65MAX OUTPUT WATTAGE[W]12001404140014041401.61404DC OUTPUT12V 100A24V 58.5A28V 50A36V 39A48V 29.2A65V 21.6ASPECIFICATIONSMODELDCS1400B12DCS1400B24DCS1400B28DCS1400B36DCS1400B48DCS1400B65VOLTAGE[VDC]200 - 435 (Surge Voltage 500V, 100ms max)INPUTCURRENT[A]*14.61typ5.34typ5.29typ5.28typ5.27typ5.28typEFFICIENCY[%]*193typ94typ94.5typ95typ95typ95typVOLTAGE[V]122428364865CURRENT[A]10058.5503929.221.6LINE REGULATION[mV]24max48max56max72max96max130maxLOAD REGULATION[mV]24max48max56max72max96max130maxRIPPLE[mVp-p]OUTPUT-10 to +100C *2 150max 150max 150max 200max 250max 400maxRIPPLE NOISE[mVp-p]-40 to -10 C *2 180max 180max 180max 240max 300max 450maxTEMPERATURE REGULATION[mV]OUTPUT VOLTAGE ADJUSTMENT RANGE *3Fixed (TRM pin open), 0 - 120% adjustable by external VR or external voltage0 to 14.40 0 to 28.80 0 to 33.60 0 to 43.20 0 to 57.60 0 to 78.00OUTPUT VOLTAGE SETTING[V]12.00 to 12.1224.00 to 24.2428.00 to 28.2836.00 to 36.3648.00 to 48.4865.00 to 65.65OVERCURRENT PROTECTION Works over 105% of rating and recovers automaticallyPROTECTIONOVERVOLTAGE PROTECTION 15.0 to 16.8 30.0 to 33.6 35.0 to 39.2 45.0 to 50.4 60.0 to 67.2 81.3 to 91.0CIRCUIT ANDREMOTE SENSINGProvidedOTHERSREMOTE ON/OFFProvidedINPUT-OUTPUT3,000VAC 1minute, Cutoff current = 10mA, 500VDC 50MW min (20±15C)INPUT-FG2,000VAC 1minute, Cutoff current = 10mA, 500VDC 50MW min (20±15C)ISOLATIONDCS1400B12/24/28/36/48 : 500VAC 1minute, Cutoff current = 100mA, 500VDC 50MW min (20±15C)OUTPUT-FGDCS1400B65: 1,200VAC 1minute, Cutoff current = 10mA, 500VDC 50MW min (20±15C)OPERATING TEMP.,HUMID.AND ALTITUDE-40 to +100C (Baseplate temperature), -40 to +85C (Ambient temperature), 20 - 95%RH (Non condensing), 5,000m (16,500 feet) maxENVIRONMENTIMPACT196.1m/s 2 , 11ms, once each X, Y and Z axisSAFETYAGENCY APPROVALSUL62368-1, C-UL (equivalent to CAN/CSA-C22.2 No.62368-1), EN62368-1OTHERS*1At rated input(280VDC) and rated load.*2Refer to instruction manual for measuring method of electric characteristics.*3If the output voltage is changed to 60% or less of the rated output voltage, the line regulation, load regulation, ripple, and ripple noise specifications may be violated.In addition, if the output voltage is set to 0V, a residual voltage will occur.DCS-2? 532 ?