title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
534/916

This page is the summary of page 534 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

RDC-DC Converters Bus Converter . Power Module TypeDCS1400BOrdering informationDC S 1400 B 28 -O1 2 3 4 5 61 Series name2 Single output3 Output wattage4 Input voltageB : 200 - 435VDC5 Output voltage6 OptionalT : with Mounting hole(f3.4 thru)R : with Remote ON/OFF(Positive logic control)N1: Auto restart from thermalprotectionP2: Built-in ORing MOSFETDCS* If remote on/off is not necessary, connect between RC & RCG.* Keep VTRM open, if output voltage adjustment is not necessary.* Keep ITRM open, if output current adjustment is not necessary.* If remote sensing is not necessary, connect between +Vout & +S and between -Vout & -S.MODELDCS1400B12DCS1400B24DCS1400B28DCS1400B36DCS1400B48DCS1400B65MAX OUTPUT WATTAGE[W]12001404140014041401.61404DC OUTPUT12V 100A24V 58.5A28V 50A36V 39A48V 29.2A65V 21.6ASPECIFICATIONSMODELDCS1400B12DCS1400B24DCS1400B28DCS1400B36DCS1400B48DCS1400B65VOLTAGE[VDC]200 - 435 (Surge Voltage 500V, 100ms max)INPUTCURRENT[A]*14.61typ5.34typ5.29typ5.28typ5.27typ5.28typEFFICIENCY[%]*193typ94typ94.5typ95typ95typ95typVOLTAGE[V]122428364865CURRENT[A]10058.5503929.221.6LINE REGULATION[mV]24max48max56max72max96max130maxLOAD REGULATION[mV]24max48max56max72max96max130maxRIPPLE[mVp-p]OUTPUT-10 to +100C *2 150max 150max 150max 200max 250max 400maxRIPPLE NOISE[mVp-p]-40 to -10 C *2 180max 180max 180max 240max 300max 450maxTEMPERATURE REGULATION[mV]OUTPUT VOLTAGE ADJUSTMENT RANGE *3Fixed (TRM pin open), 0 - 120% adjustable by external VR or external voltage0 to 14.40 0 to 28.80 0 to 33.60 0 to 43.20 0 to 57.60 0 to 78.00OUTPUT VOLTAGE SETTING[V]12.00 to 12.1224.00 to 24.2428.00 to 28.2836.00 to 36.3648.00 to 48.4865.00 to 65.65OVERCURRENT PROTECTION Works over 105% of rating and recovers automaticallyPROTECTIONOVERVOLTAGE PROTECTION 15.0 to 16.8 30.0 to 33.6 35.0 to 39.2 45.0 to 50.4 60.0 to 67.2 81.3 to 91.0CIRCUIT ANDREMOTE SENSINGProvidedOTHERSREMOTE ON/OFFProvidedINPUT-OUTPUT3,000VAC 1minute, Cutoff current = 10mA, 500VDC 50MW min (20±15C)INPUT-FG2,000VAC 1minute, Cutoff current = 10mA, 500VDC 50MW min (20±15C)ISOLATIONDCS1400B12/24/28/36/48 : 500VAC 1minute, Cutoff current = 100mA, 500VDC 50MW min (20±15C)OUTPUT-FGDCS1400B65: 1,200VAC 1minute, Cutoff current = 10mA, 500VDC 50MW min (20±15C)OPERATING TEMP.,HUMID.AND ALTITUDE-40 to +100C (Baseplate temperature), -40 to +85C (Ambient temperature), 20 - 95%RH (Non condensing), 5,000m (16,500 feet) maxENVIRONMENTIMPACT196.1m/s 2 , 11ms, once each X, Y and Z axisSAFETYAGENCY APPROVALSUL62368-1, C-UL (equivalent to CAN/CSA-C22.2 No.62368-1), EN62368-1OTHERS*1At rated input(280VDC) and rated load.*2Refer to instruction manual for measuring method of electric characteristics.*3If the output voltage is changed to 60% or less of the rated output voltage, the line regulation, load regulation, ripple, and ripple noise specifications may be violated.In addition, if the output voltage is set to 0V, a residual voltage will occur.DCS-2? 532 ?