Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
RPBA/PBWAC-DC Power Supplies Enclosed TypePBA15FOrdering informationPB A 15 F -O -O1 2 3 4 5 6Example recommended EMI/EMC filterNAC-06-472High voltage pulse noise type : NAP seriesLow leakage current type : NAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.Cover is optional*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *5C : with CoatingG : Low leakage currentE : Low leakage currentand EMI class AT : Vertical terminal blockJ1 : VH (J.S.T.) connector typeN : with Cover(UL508 is acquired[5V, 12V, 24V])N1 : with DIN rail and CoverV : Output voltage settingpotentiometer externallyMODELPBA15F-3R3PBA15F-5PBA15F-9PBA15F-12PBA15F-15PBA15F-24PBA15F-48MAX OUTPUT WATTAGE[W]9.91515.315.61516.816.8DC OUTPUT3.3V 3A5V3A9V 1.7A12V 1.3A15V 1A24V 0.7A48V 0.35ASPECIFICATIONSMODELPBA15F-3R3PBA15F-5PBA15F-9PBA15F-12PBA15F-15PBA15F-24PBA15F-48VOLTAGE[V]AC85 -264 1f or DC110 -370 (AC50 or DC70 Please refer to the instruction manual 1.1 Input voltage *3)CURRENT[A]FREQUENCY[Hz]50/60 (47 -440) or DCINPUTACIN 100V 68typ 74typ 75typ 75typ 77typ 75typ 75typEFFICIENCY[%]ACIN 200V 68typ 75typ 77typ 78typ 80typ 78typ 78typACIN 100V 15typ (Io=100%) (At cold start)INRUSH CURRENT[A]ACIN 200V 30typ (Io=100%) (At cold start)LEAKAGE CURRENT[mA]0.15/0.30max (ACIN 100V/240V 60Hz, Io=100%, According to IEC62368-1,DENAN)VOLTAGE[V]3.35912152448CURRENT[A]331.71.310.70.35LINE REGULATION[mV]*6 20max20max36max48max60max96max192maxLOAD REGULATION[mV]*6 40max40max100max100max120max150max240maxRIPPLE[mVp-p]RIPPLE NOISE[mVp-p] 0to +50C *1 120max 120max 150max 150max 150max 150max 250maxOUTPUT-10 -0C *1 160max 160max 180max 180max 180max 180max 300maxTEMPERATURE REGULATION[mV]DRIFT[mV]*2 20max20max36max48max60max96max192maxSTART-UP TIME[ms]200typ(ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.HOLD-UP TIME[ms]20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]2.85 -3.604.50 -5.507.50 -10.010.0 -13.213.2 - 18.019.2 - 27.039.0 -53.0OUTPUT VOLTAGE SETTING[V]3.30 -3.405.00 -5.159.00 -9.3612.00 - 12.4815.00 -15.6024.00 -24.9648.00 -49.92OVERCURRENT PROTECTIONWorks over 105% ofrated current and recovers automaticallyPROTECTION OVERVOLTAGE PROTECTION[V] 4.00 -5.25 5.75 -7.00 11.5 -14.0 15.0 -18.0 20.0 - 25.0 30.0 - 37.0 58.0 -65.0CIRCUIT ANDOTHERS OPERATING INDICATION LED (Green)REMOTE ON/OFFNoneINPUT-OUTPUTAC3,000V 1minute, Cutoff current =10mA, DC500V 50MWmin (At Room Temperature)ISOLATIONINPUT-FGAC2,000V 1minute, Cutoff current =10mA, DC500V 50MWmin (At Room Temperature)OUTPUT-FGAC500V 1minute, Cutoff current =25mA, DC500V 50MWmin (At Room Temperature)OPERATING TEMP.,HUMID.AND ALTITUDE-10 to +71C (Refer to“Derating”), 20 -90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 -90%RH (Non condensing) 9,000m (30,000feet) maxENVIRONMENTVIBRATION10 - 55Hz, 19.6m/s 2 (2G), 3minutes period, 60minutes each along X, Y and ZaxisIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axisSAFETY ANDAGENCY APPROVALS (At only ACinput) UL60950-1, C-UL(CSA60950-1), EN62368-1 Complies with DEN-ANNOISE CONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BREGULATIONSHARMONIC ATTENUATORComplies with IEC61000-3-2 (Not built-in to active filter *4) *7OTHERS*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN:RM101).*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 Derating is required.*4 When two or more units are used,they may not comply with the harmonic attenuator. Pleasecontact us for details.*5 Please contact us about safety approvals for the model with option.*6 Please contact us about dynamic load and input response.*7 Please contact us about class C.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.PBA/PBW-4? 52 ?