title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
54/916

This page is the summary of page 54 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

RPBA/PBWAC-DC Power Supplies Enclosed TypePBA15FOrdering informationPB A 15 F -O -O1 2 3 4 5 6Example recommended EMI/EMC filterNAC-06-472High voltage pulse noise type : NAP seriesLow leakage current type : NAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.Cover is optional*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *5C : with CoatingG : Low leakage currentE : Low leakage currentand EMI class AT : Vertical terminal blockJ1 : VH (J.S.T.) connector typeN : with Cover(UL508 is acquired[5V, 12V, 24V])N1 : with DIN rail and CoverV : Output voltage settingpotentiometer externallyMODELPBA15F-3R3PBA15F-5PBA15F-9PBA15F-12PBA15F-15PBA15F-24PBA15F-48MAX OUTPUT WATTAGE[W]9.91515.315.61516.816.8DC OUTPUT3.3V 3A5V3A9V 1.7A12V 1.3A15V 1A24V 0.7A48V 0.35ASPECIFICATIONSMODELPBA15F-3R3PBA15F-5PBA15F-9PBA15F-12PBA15F-15PBA15F-24PBA15F-48VOLTAGE[V]AC85 -264 1f or DC110 -370 (AC50 or DC70 Please refer to the instruction manual 1.1 Input voltage *3)CURRENT[A]FREQUENCY[Hz]50/60 (47 -440) or DCINPUTACIN 100V 68typ 74typ 75typ 75typ 77typ 75typ 75typEFFICIENCY[%]ACIN 200V 68typ 75typ 77typ 78typ 80typ 78typ 78typACIN 100V 15typ (Io=100%) (At cold start)INRUSH CURRENT[A]ACIN 200V 30typ (Io=100%) (At cold start)LEAKAGE CURRENT[mA]0.15/0.30max (ACIN 100V/240V 60Hz, Io=100%, According to IEC62368-1,DENAN)VOLTAGE[V]3.35912152448CURRENT[A]331.71.310.70.35LINE REGULATION[mV]*6 20max20max36max48max60max96max192maxLOAD REGULATION[mV]*6 40max40max100max100max120max150max240maxRIPPLE[mVp-p]RIPPLE NOISE[mVp-p] 0to +50C *1 120max 120max 150max 150max 150max 150max 250maxOUTPUT-10 -0C *1 160max 160max 180max 180max 180max 180max 300maxTEMPERATURE REGULATION[mV]DRIFT[mV]*2 20max20max36max48max60max96max192maxSTART-UP TIME[ms]200typ(ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.HOLD-UP TIME[ms]20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]2.85 -3.604.50 -5.507.50 -10.010.0 -13.213.2 - 18.019.2 - 27.039.0 -53.0OUTPUT VOLTAGE SETTING[V]3.30 -3.405.00 -5.159.00 -9.3612.00 - 12.4815.00 -15.6024.00 -24.9648.00 -49.92OVERCURRENT PROTECTIONWorks over 105% ofrated current and recovers automaticallyPROTECTION OVERVOLTAGE PROTECTION[V] 4.00 -5.25 5.75 -7.00 11.5 -14.0 15.0 -18.0 20.0 - 25.0 30.0 - 37.0 58.0 -65.0CIRCUIT ANDOTHERS OPERATING INDICATION LED (Green)REMOTE ON/OFFNoneINPUT-OUTPUTAC3,000V 1minute, Cutoff current =10mA, DC500V 50MWmin (At Room Temperature)ISOLATIONINPUT-FGAC2,000V 1minute, Cutoff current =10mA, DC500V 50MWmin (At Room Temperature)OUTPUT-FGAC500V 1minute, Cutoff current =25mA, DC500V 50MWmin (At Room Temperature)OPERATING TEMP.,HUMID.AND ALTITUDE-10 to +71C (Refer to“Derating”), 20 -90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 -90%RH (Non condensing) 9,000m (30,000feet) maxENVIRONMENTVIBRATION10 - 55Hz, 19.6m/s 2 (2G), 3minutes period, 60minutes each along X, Y and ZaxisIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axisSAFETY ANDAGENCY APPROVALS (At only ACinput) UL60950-1, C-UL(CSA60950-1), EN62368-1 Complies with DEN-ANNOISE CONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BREGULATIONSHARMONIC ATTENUATORComplies with IEC61000-3-2 (Not built-in to active filter *4) *7OTHERS*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN:RM101).*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 Derating is required.*4 When two or more units are used,they may not comply with the harmonic attenuator. Pleasecontact us for details.*5 Please contact us about safety approvals for the model with option.*6 Please contact us about dynamic load and input response.*7 Please contact us about class C.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.PBA/PBW-4? 52 ?