title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
540/916

This page is the summary of page 540 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

DC-DC Converters Bus Converter . Power Module TypeDHS50AOrdering informationDH S 50 A 05 -O1 2 3 4 5 6R* Providing heat sinkas option1 Series name2 Single output3 Output wattage4 A : DC60-160V5 Output voltage6 OptionalT : with Mounting hole(f3.4 thru)DHSMODEL DHS50A05 DHS50A12 DHS50A15 DHS50A24MAX OUTPUT WATTAGE[W] 50.0 50.4 51.0 50.4DC OUTPUT 5V 10A 12V 4.2A 15V 3.4A 24V 2.1ASPECIFICATIONSINPUTOUTPUTMODEL DHS50A05 DHS50A12 DHS50A15 DHS50A24VOLTAGE[V] DC60 - 160CURRENT[A] *1 0.55A 0.55A 0.55A 0.55AEFFICIENCY[%] *1 84.0typ 86.0typ 86.0typ 86.0typVOLTAGE[V] 5 12 15 24CURRENT[A] 10 4.2 3.4 2.1LINE REGULATION[mV] 10max 24max 30max 48maxLOAD REGULATION[mV] 10max 24max 30max 48maxRIPPLE[mVp-p]RIPPLE NOISE[mVp-p]TEMPERATURE REGULATION[mV]0 to +100C *2 80max 120max 120max 120max-40 to 0C *2 120max 150max 150max 150max0 to 15% Load *2 160max 240max 240max 240max0 to +100C *2 120max 150max 150max 150max-40 to 0C *2 200max 200max 200max 250max0 to 15% Load *2 240max 300max 300max 300max0 to +65C 50max 120max 150max 240max-40 to +100C 100max 240max 300max 480maxDRIFT[mV] *3 20max 40max 60max 90maxSTART-UP TIME[ms]200max (DCIN 110V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V] *4Fixed (TRM pin open), adjustable by external VR or external voltage4.50 - 6.00 10.80 - 13.20 13.50 - 16.50 21.60 - 26.40OUTPUT VOLTAGE SETTING[V]4.97 - 5.1311.91 - 12.2914.76 - 15.2423.62 - 24.38OVERCURRENT PROTECTIONWorks over 105% of rating and recovers automaticallyPROTECTIONOVERVOLTAGE PROTECTION[V] 6.30 - 7.60 13.90 - 17.55 17.25 - 21.75 27.60 - 34.80CIRCUIT ANDOTHERS REMOTE SENSING nothingREMOTE ON/OFFProvided (Negative Logic L : ON, H :OFF)INPUT-OUTPUTAC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)ISOLATIONINPUT-FGAC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)OUTPUT-FGAC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20±15C)OPERATING TEMP.,HUMID.AND ALTITUDE-40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to“Derating”), 3,000m (10,000 feet) maxENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each along X, Y and Z axis Complies with IEC61373 Category 1 Class BSAFETYAGENCY APPROVALSUL60950-1, C-UL (CSA60950-1), EN62368-1OTHERS*1At rated input(DC110V) and rated load.*2Ripple and ripple noise is measured by using measuring board. Refer to the manual*3Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.*4Refer to the manual for input range.DHS-2? 538 ?