title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
556/916

This page is the summary of page 556 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

AC-DC Power Supplies Bus Converter . Power Module TypeTUNS50FOrdering informationTUN S 50 F 05 -O1 2 3 4 5 6R* Providing heat sinkas option1 Series name2 Single output3 Output wattage4 Universal Input5 Output voltage6 OptionalT : with Mounting hole(f3.4 thru)*Avoid short circuit between +BC and -BC. It may cause the failure of inside components.*Keep TRM open, if output voltage adjustment is not necessary.TUNSMODELTUNS50F05TUNS50F12TUNS50F24MAX OUTPUT WATTAGE[W]50.050.450.4DC OUTPUT5V 10A12V 4.2A24V 2.1ASPECIFICATIONSMODELTUNS50F05TUNS50F12TUNS50F24VOLTAGE[V]AC85 - 264 1f (Refer to“Derating”)CURRENT[A]FREQUENCY[Hz]50/60 (47 - 63)INPUTEFFICIENCY[%]POWER FACTOR (Io=100%)INRUSH CURRENTLimited by external components (Thermistor)LEAKAGE CURRENT[mA]0.75max (ACIN 240V 60Hz, Io=100%, According to IEC62368-1)VOLTAGE[V]51224CURRENT[A]104.22.1LINE REGULATION[mV]10max24max48maxLOAD REGULATION[mV]10max24max48max0 to +100C *180max120max120maxRIPPLE[mVp-p]-40 to 0C *1120max150max150max0 to 15% Load *1200max280max380maxOUTPUT0 to 15% Load *1280max360max460maxTEMPERATURE REGULATION[mV]DRIFT[mV]*220max40max90maxOUTPUT VOLTAGE ADJUSTMENT RANGE[V]Fixed (TRM pin open), adjustable by external resistor or external signal4.50 - 6.00 10.80 - 13.20 21.60 - 26.40OUTPUT VOLTAGE SETTING[V]4.97 - 5.1311.91 - 12.2923.62 - 24.38PROTECTIONCIRCUIT ANDOTHERSOVERCURRENT PROTECTIONWorks over 105% of rating and recovers automaticallyOVERVOLTAGE PROTECTION[V]6.30 - 7.0013.90 - 16.3527.60 - 32.40REMOTE SENSINGNot providedREMOTE ON/OFFNot providedINPUT-OUTPUTAC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)ISOLATIONINPUT-FGAC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)OUTPUT-FGAC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20±15C)OPERATING TEMP.,HUMID.AND ALTITUDE-40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to“Derating”), 3,000m (10,000 feet) maxENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each along X, Y and Z axisSAFETY ANDAGENCY APPROVALSUL60950-1, C-UL (CSA60950-1), EN62368-1NOISE REGULATIONSHARMONIC ATTENUATORComplies with IEC61000-3-2 (Class A) *3OTHERS*1Refer to instruction manual for measuring method of electric characteristics.*2Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.*3Please contact us about another class.TUNS-2? 554 ?