title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
576/916

This page is the summary of page 576 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

AC-DC Power Supplies Power Module TypeTUXS200FOrdering informationTUX S 200 F 50 -O1 2 3 4 5 6R1 Series name2 Single output3 Output wattage4 Universal Input5 Output voltage6 OptionalT : with Mounting hole(f3.4 thru)N : Auto restart in protectioncircuit working*Avoid short circuit between +BC and -BC. It may cause the failure of inside components.*Keep TRM open, if output voltage adjustment is not necessary.TUXSMODELTUXS200F24TUXS200F28TUXS200F32TUXS200F42TUXS200F50MAX OUTPUT WATTAGE[W]199.2196.0198.4197.4200.0DC OUTPUT24V 8.3A28V 7.0A32V 6.2A42V 4.7A50V 4.0ASPECIFICATIONSMODELTUXS200F24TUXS200F28TUXS200F32TUXS200F42TUXS200F50VOLTAGE[V]AC85 - 264 1fCURRENT[A]FREQUENCY[Hz]50/60 (45 - 66)INPUTEFFICIENCY[%]POWER FACTOR (Io=100%)INRUSH CURRENTLimited by external components (Thermistor)LEAKAGE CURRENT[mA]0.75max (ACIN 240V 60Hz, Io=100%, According to IEC62368-1)VOLTAGE[V]2428324250CURRENT[A]8.37.06.24.74.0LINE REGULATION[mV]48max56max64max84max100maxLOAD REGULATION[mV]48max56max64max84max100maxRIPPLE[mVp-p]OUTPUTRIPPLE NOISE[mVp-p]TEMPERATURE REGULATION[mV]DRIFT[mV]*296max112max128max168max200maxOUTPUT VOLTAGE ADJUSTMENT RANGE[V]Fixed (TRM pin open), adjustable by external resistor or external signal21.60 - 26.40 25.20 - 30.80 28.80 - 35.20 37.80 - 46.20 45.00 - 55.00OUTPUT VOLTAGE SETTING[V]23.62 - 24.3827.55 - 28.4531.49 - 32.5141.33 - 42.6749.20 - 50.80PROTECTIONCIRCUIT ANDOTHERSOVERCURRENT PROTECTIONWorks over 105% of rating and recovers automaticallyOVERVOLTAGE PROTECTION[V]27.60 - 28.8032.20 - 33.6036.80 - 38.4048.30 - 50.4057.50 - 60.00REMOTE SENSINGNot providedREMOTE ON/OFFNot providedINPUT-OUTPUTAC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)ISOLATIONINPUT-FGAC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)OUTPUT-FGAC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20±15C)OPERATING TEMP.,HUMID.AND ALTITUDE-40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to ?Derating”), 4,000m (13,000 feet) maxENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each along X, Y and Z axisSAFETY ANDAGENCY APPROVALSUL60950-1, C-UL (CSA60950-1), EN62368-1NOISE REGULATIONSHARMONIC ATTENUATORComplies with IEC61000-3-2 (Class A) *3OTHERS*1Refer to instruction manual for measuring method of electric characteristics.*2Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.*3Please contact us about another class.TUXS-4? 574 ?