Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
AC-DC Power Supplies Enclosed TypePDA100FOrdering informationPD A 100 F -O -O1 2 3 4 5 6RExample recommended EMI/EMC filterNAC-06-472High voltage pulse noise type : NAP seriesLow leakage current type : NAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *1N : with coverC: with CoatingG: LOW leakage currentJ1 : VH(J.S.T.) Connector type(only -12, -15, -24, -36, -48)N1 : with DIN rail and CoverT5 : UL508[24V]For option details, refer toInstruction Manual 8.1.*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.MODELPDA100F-3R3PDA100F-5PDA100F-12PDA100F-15PDA100F-24PDA100F-36PDA100F-48MAX OUTPUT WATTAGE[W]*266100102105108100.8100.8DC OUTPUT*23.3V 20A5V 20A12V 8.5A15V 7A24V 4.5A36V 2.8A48V 2.1ASPECIFICATIONSMODELPDA100F-3R3PDA100F-5PDA100F-12PDA100F-15PDA100F-24PDA100F-36PDA100F-48VOLTAGE[VAC]*285 - 264 1f(Refer to Instruction Manual 1.1)CURRENT[A]FREQUENCY[Hz]50 / 60 (45 - 66)ACIN 100V 85.0typ 87.0typ 88.5typ 88.5typ 87.5typ 87.5typ 88.0typEFFICIENCY[%]INPUTACIN 230V 86.5typ 89.5typ 91.0typ 91.0typ 89.5typ 90.0typ 90.5typPOWER FACTORACIN 100V0.97typ0.97typ(Io=100%)ACIN 230V0.81typ0.87typACIN 100V 15typ (Io=100%) at cold startINRUSH CURRENT[A]ACIN 230V 35typ (Io=100%) at cold startLEAKAGE CURRENT[mA]0.4 / 0.75 max (ACIN 100V / 240V, 60Hz, Io=100%, According to IEC62368-1, and DEN-AN)VOLTAGE[V]3.351215243648CURRENT[A]*220208.574.52.82.1LINE REGULATION[mV]*320max20max48max60max96max144max192maxLOAD REGULATION[mV]*340max40max100max120max150max240max240maxRIPPLE[mVp-p]OUTPUT0 to +50C 120max 120max 150max 150max 150max 250max 250maxRIPPLE NOISE[mVp-p]-20 to 0C 160max 160max 180max 180max 180max 300max 300max*4Io=0 to 15%360max360max400max600max600max600max600maxTEMPERATURE REGULATION[mV]0 to +50C 50max 50max 120max 150max 240max 360max 480max-20 to +50C 60max 60max 150max 180max 290max 450max 600maxDRIFT[mV]*520max20max48max60max96max144max192maxSTART-UP TIME[ms]100typ (ACIN 100V, Io=100%)HOLD-UP TIME[ms]20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]2.85 to 3.634.00 to 5.5010.00 to 13.2013.20 to 18.0019.20 to 27.0028.80 to 39.6039.00 to 53.00OUTPUT VOLTAGE SETTING[V]3.30 to 3.405.00 to 5.1512.00 to 12.4815.00 to 15.6024.00 to 24.9636.00 to 37.4448.00 to 49.92PROTECTION OVERCURRENT PROTECTIONWorks over 105% of rating and recovers automaticallyCIRCUIT AND OVERVOLTAGE PROTECTION4.00 to 5.255.75 to 7.0015.00 to 18.0020.00 to 25.0030.00 to 37.0043.00 to 50.0058.00 to 67.00OTHERSREMOTE SENSINGNot providedINPUT-OUTPUT3,000VAC 1minute, Cutoff current = 10mA, 500VDC 100MW min (At Room Temperature)ISOLATIONINPUT-FG2,000VAC 1minute, Cutoff current = 10mA, 500VDC 100MW min (At Room Temperature)OUTPUT-FG500VAC 1minute, Cutoff current = 25mA, 500VDC 100MW min (At Room Temperature)OPERATING TEMPERATURE,HUMID *2-20 to +70C, 20 - 90%RH (Non condensing)ENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axisSAFETY ANDAGENCY APPROVALSUL62368-1, C-UL (equivalent to CAN/CSA-C22.2No.62368-1), EN62368-1, Complies with DEN-ANNOISECONDUCTED NOISEComplies with CISPR11-B, CISPR32-B, EN55011-B, EN55032-B, FCC Part15-B, FCC Part18-B, VCCI-BREGULATIONSHARMONIC ATTENUATOR *6Complies with IEC61000-3-2 (Class A)OTHERS*1 The listed options may affect the published standard specifications. Please contact us fordetailed product specifications.*2 Derating is required.Please contact us for DC input.*3 At low load conditions, the burst mode operation will start. To check load regulation, you willneed to measure the characteristics at average mode with instruments.*4 This is the value that measured on measuring board with capacitor of 22mF at 150mm fromoutput terminal.Measured by 20MHz oscilloscope or Ripple-Noise meterPDA-8(Equivalent to KEISOKU-GIKEN:RM104).Ripple and ripple noise spec is change at Io=0 to 15% by burst operation.*5 Drift is the change in DC output for an eight hour period after a half-hour warm-up at25C, with the input voltage held constant at the rated input/output.*6 Please contact us about another class. When two or more units are operating it maynot comply with the IEC61000-3-2. Please contact us for details.* To meet the specification, do not operate overload condition.* Parallel operation is not possible.* Sound noise may be generated by power supply in case of pulse load.