title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
60/916

This page is the summary of page 60 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

RPBA/PBWAC-DC Power Supplies Enclosed TypePBA75FOrdering informationPB A 75 F -5 -O1 2 3 4 5 6Example recommended EMI/EMC filterNAC-06-472High voltage pulse noise type : NAP seriesLow leakage current type : NAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *5C : with CoatingG : Low leakage current(0.15mA max / ACIN 240V)E : Low leakage currentand EMI class A(0.5mA max / ACIN 240V)T : Vertical terminal blockJ1 : VH (J.S.T.) connector typeR : with Remote ON/OFFN : with Cover(Only 24V UL508 is acquired)N1 : with DIN rail and CoverV : Output voltage settingpotentiometer externallyCover is optional*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.MODELPBA75F-3R3PBA75F-5PBA75F-9PBA75F-12PBA75F-15PBA75F-24PBA75F-36PBA75F-48MAX OUTPUT WATTAGE[W]49.57575.675.67576.875.676.8DC OUTPUT3.3V 15A5V 15A9V 8.4A12V 6.3A15V 5A24V 3.2A36V 2.1A48V 1.6ASPECIFICATIONSMODELPBA75F-3R3PBA75F-5PBA75F-9PBA75F-12PBA75F-15PBA75F-24PBA75F-36PBA75F-48VOLTAGE[V]AC85 - 264 1f or DC120 -370 (AC50 or DC70 Please refer to the instruction manual 1.1 Input voltage *4)CURRENT[A]FREQUENCY[Hz]50/60 (47 -63)ACIN 100V 77typ 81typ 80typ 81typ 82typ 83typ 84typ 84typEFFICIENCY[%]INPUTACIN 200V 78typ 83typ 82typ 83typ 84typ 85typ 86typ 86typPOWER FACTOR(Io=100%)ACIN 100V 15typ (Io=100%) (At cold start)INRUSH CURRENT[A]ACIN 200V 30typ (Io=100%) (At cold start)LEAKAGE CURRENT[mA]0.4/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC62368-1,DENAN)VOLTAGE[V]3.3591215243648CURRENT[A]15158.46.353.22.11.6LINE REGULATION[mV]20max20max36max48max60max96max144max192maxLOAD REGULATION[mV]40max40max100max100max120max150max240max240maxRIPPLE[mVp-p]0to +50C *1 120max 120max 150max 150max 150max 150max 250max 250maxRIPPLE NOISE[mVp-p]OUTPUT-10 -0C *1 160max 160max 180max 180max 180max 180max 300max 300maxTEMPERATURE REGULATION[mV]DRIFT[mV]*2 20max20max36max48max60max96max144max192maxSTART-UP TIME[ms]350typ(ACIN 100V, Io=100%)HOLD-UP TIME[ms]20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]2.85 -3.634.00 - 5.507.50 - 10.010.0 -13.213.2 - 18.019.2 - 27.028.8 - 39.639.0 -53.0OUTPUT VOLTAGE SETTING[V]3.30 -3.405.00 - 5.159.00 - 9.3612.00 -12.4815.00 -15.6024.00 - 24.9636.00 - 37.4448.00 -49.92OVERCURRENT PROTECTIONWorks over 105% of rated current and recovers automaticallyPROTECTION OVERVOLTAGE PROTECTION[V] 4.00 -5.25 5.75 - 7.00 11.5 - 14.0 15.0 -18.0 20.0 - 25.0 30.0 - 37.0 43.0 - 50.0 58.0 -65.0CIRCUIT ANDOTHERS OPERATING INDICATION LED (Green)REMOTE ON/OFFOptional (Required external power source)INPUT-OUTPUT-RC*3 AC3,000V 1minute, Cutoff current =10mA, DC500V 50MWmin (At Room Temperature)ISOLATIONINPUT-FGAC2,000V 1minute, Cutoff current =10mA, DC500V 50MWmin (At Room Temperature)OUTPUT-RC-FG*3 AC500V 1minute, Cutoff current =100mA, DC500V 50MWmin (At Room Temperature)OPERATING TEMP.,HUMID.AND ALTITUDE-10 to +71C (Refer to“Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxENVIRONMENTVIBRATION10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Yand Z axisIMPACT196.1m/s2 (20G), 11ms, once each X, Y and Z axisSAFETY AND AGENCY APPROVALS (At only ACinput)UL60950-1, C-UL(CSA60950-1), EN62368-1 Complies with DEN-ANNOISECONDUCTED NOISEComplies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BREGULATIONSHARMONIC ATTENUATORComplies with IEC61000-3-2 *6OTHERS*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN:RM101).*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 Applicable when Remote ON/OFF(optional) is added. RC is insulated with input, output andFG.*4 Derating is required.*5 Please contact us about safety approvals for the model with option.*6 Please contact us about class C.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.PBA/PBW-10? 58 ?