title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
60/1330

This page is the summary of page 60 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

AC-DC Power Supplies Enclosed TypePDA150FOrdering informationPD A 150 F -O -O1 2 3 4 5 6RExample recommended EMI/EMC filterNAC-06-472High voltage pulse noise type : NAP seriesLow leakage current type : NAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *1N : with coverC: with CoatingG: LOW leakage currentJ1 : VH(J.S.T.) Connector type(only -12, -15, -24, -36, -48)N1 : with DIN rail and CoverT5 : UL508[24V]For option details, refer toInstruction Manual 8.1.*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.MODELPDA150F-3R3PDA150F-5PDA150F-12PDA150F-15PDA150F-24PDA150F-36PDA150F-48MAX OUTPUT WATTAGE[W]*299150156150156154.8158.4DC OUTPUT*23.3V 30A5V 30A12V 13A15V 10A24V 6.5A36V 4.3A48V 3.3ASPECIFICATIONSMODELPDA150F-3R3PDA150F-5PDA150F-12PDA150F-15PDA150F-24PDA150F-36PDA150F-48VOLTAGE[VAC]*285 - 264 1f(Refer to Instruction Manual 1.1)CURRENT[A]FREQUENCY[Hz]50 / 60 (45 - 66)ACIN 100V 84.0typ 85.0typ 87.0typ 88.5typ 87.0typ 88.0typ 88.5typEFFICIENCY[%]INPUTACIN 230V 86.0typ 87.5typ 89.0typ 89.5typ 89.0typ 90.0typ 90.5typPOWER FACTORACIN 100V0.97typ0.97typ(Io=100%)ACIN 230V0.84typ0.87typACIN 100V 15typ (Io=100%) at cold startINRUSH CURRENT[A]ACIN 230V 35typ (Io=100%) at cold startLEAKAGE CURRENT[mA]0.4 / 0.75 max (ACIN 100V / 240V, 60Hz, Io=100%, According to IEC62368-1, and DEN-AN)VOLTAGE[V]3.351215243648CURRENT[A]303013106.54.33.3LINE REGULATION[mV]*320max20max48max60max96max144max192maxLOAD REGULATION[mV]*340max40max100max120max150max240max240maxRIPPLE[mVp-p]OUTPUT0 to +50C 120max 120max 150max 150max 150max 250max 250maxRIPPLE NOISE[mVp-p]-20 to 0C 160max 160max 180max 180max 180max 300max 300max*4Io=0 to 15%360max360max400max600max600max600max600maxTEMPERATURE REGULATION[mV]0 to +50C 50max 50max 120max 150max 240max 360max 480max-20 to +50C 60max 60max 150max 180max 290max 450max 600maxDRIFT[mV]*520max20max48max60max96max144max192maxSTART-UP TIME[ms]120typ (ACIN 100V, Io=100%)HOLD-UP TIME[ms]20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]2.85 to 3.634.00 to 5.5010.00 to 13.2013.20 to 18.0019.20 to 27.0028.80 to 39.6039.00 to 53.00OUTPUT VOLTAGE SETTING[V]3.30 to 3.405.00 to 5.1512.00 to 12.4815.00 to 15.6024.00 to 24.9636.00 to 37.4448.00 to 49.92PROTECTION OVERCURRENT PROTECTIONWorks over 105% of rating and recovers automaticallyCIRCUIT AND OVERVOLTAGE PROTECTION4.00 to 5.255.75 to 7.0015.00 to 18.0020.00 to 25.0030.00 to 37.0043.00 to 50.0058.00 to 67.00OTHERSREMOTE SENSINGNot providedINPUT-OUTPUT3,000VAC 1minute, Cutoff current = 10mA, 500VDC 100MW min (At Room Temperature)ISOLATIONINPUT-FG2,000VAC 1minute, Cutoff current = 10mA, 500VDC 100MW min (At Room Temperature)OUTPUT-FG500VAC 1minute, Cutoff current = 25mA, 500VDC 100MW min (At Room Temperature)OPERATING TEMPERATURE,HUMID *2-20 to +70C, 20 - 90%RH (Non condensing)ENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axisSAFETY ANDAGENCY APPROVALSUL62368-1, C-UL (equivalent to CAN/CSA-C22.2No.62368-1), EN62368-1, Complies with DEN-ANNOISECONDUCTED NOISEComplies with CISPR11-B, CISPR32-B, EN55011-B, EN55032-B, FCC Part15-B, FCC Part18-B, VCCI-BREGULATIONSHARMONIC ATTENUATOR *6Complies with IEC61000-3-2 (Class A)OTHERS*1 The listed options may affect the published standard specifications. Please contact us fordetailed product specifications.*2 Derating is required.Please contact us for DC input.*3 At low load conditions, the burst mode operation will start. To check load regulation, you willneed to measure the characteristics at average mode with instruments.*4 This is the value that measured on measuring board with capacitor of 22mF at 150mm fromoutput terminal.Measured by 20MHz oscilloscope or Ripple-Noise meterPDA-10(Equivalent to KEISOKU-GIKEN:RM104).Ripple and ripple noise spec is change at Io=0 to 15% by burst operation.*5 Drift is the change in DC output for an eight hour period after a half-hour warm-up at25C, with the input voltage held constant at the rated input/output.*6 Please contact us about another class. When two or more units are operating it maynot comply with the IEC61000-3-2. Please contact us for details.* To meet the specification, do not operate overload condition.* Parallel operation is not possible.* Sound noise may be generated by power supply in case of pulse load.