Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
AME seriesTerminal Blocks? Output module42110 935211-Output (M4)2+Output (M4)3CN3 (Connector for functions)4LED (DC_OK)5Potentiometer to adjust output voltage2 157 96 810 943211-Output for V22+Output for V23-Output for V14+Output for V15CN3 (Connector for function)6LED (DC_OK for V2)7LED (DC_OK for V1)8Potentiometer to adjust output voltage (V2)9Potentiometer to adjust output voltage (V1)Module : A-H,J-M,S-V,E4-H4,V4,V5Module : RPin configuration and function of CN3Applying module : A-D,J-MApplying Module : E4-H4,E-H,S-V,V4,V5Applying Module : RPin No.GroundGroundGroundFunctionFunctionFunctionlevellevellevel1RC: Remote ON/OFFRCGRC: Remote ON/OFFRCGV1_RC: Remote ON/OFFV1_RCG2RCG: Remote ON/OFF groundRCGRCG: Remote ON/OFF groundRCGV1_RCG : Remote ON/OFF groundV1_RCG3LV: LV AlarmLVGLV: LV AlamLVGV1_LV: LV AlamV1_LVG4LVG: LV Alarm groundLVGLVG: LV Alam groundLVGV1_LVG: LV Alam groundV1_LVG5N.C.: No connection―+S: + Remote sensingCOMN.C.: No onnection―6N.C.: No connection―-S: - Remote sensingCOMN.C.: No onnection―7N.C.: No connection―COM: Common ground for signalCOMV2_RC: Remote ON/OFFV2_RCG8N.C.: No connection―ITRM: Output current adjustmentCOMV2_RCG : Remote ON/OFF groundV2_RCG9N.C.: No connection―VTR_EN : Enable VTRMCOMV2_LV: LV AlamV2_LVG10N.C.: No connection―VTRM: Output voltage adjustmentCOMV2_LVG: LV Alam groundV2_LVG* Do not connect anything to N.C. pins.Matching connectors and terminalsConnectorHousingTerminalMfr.CN3S10B-PHDSSPHDR-10VSReel : SPHD-002T-P0.5Loose : BPHD-001T-P0.5 *1J.S.TBPHD-002T-P0.5 *1*1 The manufacturer prepares only the ratchet hand.AMEAssembling and Installation Method!The unit has cooling fans.Air flowEnsure that the inlet and outlet vents are not blocked.Output!If the unit is used in dusty environment, please considermoduleinstalling the air fi lter so that cooling effi ciencywill not get worse. In that case, please pay suffi cientattention to airfl ow.!Figures to the right are the recommended installationmethod when the unit is mounted by screws. Whenthe unit is installed by any other method, please takeCN1Topinto account of its weight and secure it.TopTopCN1!Avoid the D installation method in the fi gure to theCN1right because it will cause stress on the mountingholes.ABC!Maximum length from the outside of the unit of theChassis ofmounting screws is 6mm so that the isolation to internalcomponents is ensured. (Refer to right fi gure).customer systemAME seriesChassis of!Applicable Wire for module RApplicable WireSolid wireDiameter 0.5mm to 1.3mm (AWG.24 to AWG.16)Screw M4Standed wire0.2mm 2 to 1.5mm 2 (AWG.24 to AWG.16)6mm maxSheath strip length8mm to 9mmFANTOPNOCN1DAME-8 ? 598 ?