title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
612/916

This page is the summary of page 612 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

RAC-DC Power Supplies DIN Rail TypeKHEA/KHNA120FUL508Ordering informationKHO A -120 F -24 -O1 2 3 4 5 6Example recommended EMI/EMC filterNAC-04-472-DHigh voltage pulse noise type : NAP seriesLow leakage current type : NAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.1 Series nameKHE:Euro style I/O terminalsKHN:Barrier blocks styleI/O terminals2 Single output3 Output wattage4 Universal input5 Output voltage6 OptionC : with CoatingN2 : Screw mountingKH*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.MODELKHEA / KHNA120F-24MAX OUTPUT WATTAGE[W]120DC OUTPUT24V 5A (Peak 7.5A)SPECIFICATIONSMODELKHEA / KHNA120F-24VOLTAGE[V]AC85 - 264 1f or DC88 - 370 *10CURRENT[A]FREQUENCY[Hz]50 / 60 (45 - 66) or DCACIN 115V 90typEFFICIENCY[%]INPUTACIN 230V 92typPOWER FACTORINRUSH CURRENT[A]ACIN 115V15typ (at cold start Ta=25C)*1 ACIN 230V30typ (at cold start Ta=25C)LEAKAGE CURRENT[mA]0.45 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC62368-1 and DEN-AN)VOLTAGE[V]24CURRENT[A]5PEAK CURRENT[A]*27.5LINE REGULATION[mV]*396maxLOAD REGULATION[mV]*3150max *40 to +70C120maxRIPPLE[mVp-p]*5 -25 - 0C240maxIo=0 - 30%240max *4OUTPUTIo=0 - 30%300max *40 to +70C 240max *4TEMPERATURE REGULATION[mV]-25 to +70C 360max *4DRIFT[mV]*696maxSTART-UP TIME[ms]750max (ACIN 115V, Io=100%)HOLD-UP TIME[ms]20typ (ACIN 115V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]22.5 to 28.5OUTPUT VOLTAGE SETTING[V]24.0±1.0%OVERCURRENT PROTECTIONWorks over 101% of peak current and recovers automaticallyOVERVOLTAGE PROTECTION[V] 30.0 to 36.0PROTECTIONREMOTE ON/OFF (RC) ProvidedCIRCUIT ANDDC_OK LAMPLED (Green)OTHERSALARM LAMPLED (Red)DC_OK CONTACTRelay contact 30VDC 1A max, 30VAC 0.5A max (resistive load) (Only KHEA)INPUT-OUTPUTAC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min(At Room Temperature)ISOLATIONOUTPUT-RC, DC_OKAC500V 1minute, Cutoff current = 100mA, DC500V 50MW min(At Room Temperature)OPERATING TEMP.,HUMID.AND ALTITUDE-25 to +70C, 20 - 90%RH (Non condensing), Type tested for -40C start-up (Refer to“Derating”)ENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axis (Packing state)AC input UL60950-1, C-UL (CSA60950-1), EN62368-1, UL508, UL121201, ATEX, GL, Complies with DEN-ANSAFETY AND AGENCY APPROVALSDC input UL60950-1, C-UL (CSA60950-1), EN62368-1NOISECONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-BREGULATIONSHARMONIC ATTENUATOR Complies with IEC61000-3-2(Class A) *7CASE SIZE*837X124X117mm (WXHXD) [1.46X4.88X4.61 inches]OTHERSWEIGHT580g maxCOOLING METHODConvectionKH-8? 610 ?